4.3 Article

Mechanochemical Endovenous Ablation of the Saphenous Vein: A Look at Contemporary Outcomes

期刊

ANNALS OF VASCULAR SURGERY
卷 82, 期 -, 页码 7-12

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.avsg.2021.11.019

关键词

-

向作者/读者索取更多资源

This study investigated the initial procedural experience and clinical presentation of patients undergoing mechanochemical ablation (MOCA) at a single institution. The results showed a successful thrombosis rate of 92.7% using MOCA, with no evidence of a learning curve. The study concluded that MOCA ablation of the greater saphenous vein is a safe procedure with good technical success.
Background: Endovenous ablation techniques have replaced greater saphenous vein (GSV) ligation and stripping for treatment of venous insufficiency. Our objective was to investigate our initial procedural experience and clinical presentation of patients undergoing mechanochemical ablation (MOCA) at a single institution. We hypothesized that closure level and success rate improved over time and were comparable to other endovenous ablation techniques. Methods: We retrospectively reviewed all MOCA procedures performed at the Greater Los Angeles Veterans Affairs Hospital from 2015 - 2020. Variables included CEAP and VCSS scores, patient symptoms, post procedure duplex ultrasound, closure level, and need for anticoagulation. Success was defined as GSV thrombosis on initial post procedure duplex ultrasound. Procedure associated extension of thrombus into the deep veins was defined using the American Venous Forum (AVF) endothermal heat induced thrombosis (EHIT) classification. Results: 104 venous ablation procedures were performed on 86 patients. Eleven (12.8%) patients received bilateral interventions, and six (7%) patients had asynchronous interventions on the same leg. The average age was 58.4 years (SD 12) and 93% were male. Pre-procedural symptoms included pain (102, 98.1%), varicose veins (87, 83.7%), edema (58, 55.8%), and active ulcers (19, 18.3%). A CEAP category of C2 was the most common indication (34.6%), followed by C3 (22.1%) and C6 (21.2%). Forty-five (43.2%) patients had deep system reflux, and 53% had concomitant phlebectomies. Average VCSS score was 7.5 (SD 3.5).We observed a GSV ablation rate of 92.7% (n = 89) in the 96 procedures which had post-procedure follow up, with no temporal evidence of a learning curve. On post procedure duplex of the 89 technically successful ablations, 77 (86.5%) patients had AVF EHIT level 1 closure, three (3.4%) had level 2 closure, eight (8.9%) had level 3 closure, and one had a level 4 closure. Fourteen (15.7%) patients were newly started on anticoagulation for an average of 33.2 days (SD 34.1). Of the 19 legs treated for active venous ulcers, 13 (68.4%) had improvement or resolution of their venous ulcers. No pulmonary embolic complications were reported. Conclusions: We observed a successful GSV thrombosis rate of 92.7% using MOCA without evidence of a learning curve and comparable to that reported in the literature. The rate of thrombus extension into the deep veins was 14.6%, with no adverse effects associated with anticoagulation or clinically significant sequelae of AVF EHIT level 2 or greater. Comparisons with MOCA associated thrombus extension into deep veins in the literature are limited as post procedure screening duplex are not standard of care. However, we demonstrated that MOCA ablation of the GSV is a safe procedure that may be performed with good technical success.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据