4.8 Article

Sensitive, Signal-Modulation Strategy for Discrimination of ECLS pectra and Investigation of Mutual Interactions of Emitters

期刊

ANALYTICAL CHEMISTRY
卷 94, 期 8, 页码 3637-3644

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c05217

关键词

-

资金

  1. National Natural Science Foundation of China [21874083, 22174087]
  2. Natural Science Foundation of Shandong Province of China [ZR2021MB077]
  3. Fundamental Research Funds of Shandong University [ZY202006]

向作者/读者索取更多资源

In this study, a modulating strategy involving a band-pass filter is proposed to determine the electrochemiluminescence (ECL) spectrum. The strategy allows for the upgrade of a conventional ECL analyzer to a highly sensitive ECL spectrometer without changing the hardware. The strategy enables the determination of ultra-weak emission spectra and the demonstration of the interaction between co-existing emitters.
The intensity of electrochemiluminescence (ECL) usually changes rapidly with the progress of the electrochemical process, making it difficult to determine the ECL spectrum with a conventional photomultiplier in a wavelength scan model. Herein, a band-passfilter (BPF)-involved modulating strategy is proposed to upgrade a conventional ECL analyzer to a highly sensitive ECL spectrometer without changing its hardware. The ECL spectrum can be figured out by rapidly and/or continuously modulating a part of the ECL intensity-time curve with a BPF array of different central wavelengths as well as correcting the ECL intensity at different measurement times by a univariate cubic polynomial model. This strategy not only can determine the spectrum of ultra-weak emission with high sensitivity via merely modulating the emission within a short period, including the weak self-ECL from either Ru(bpy)32+or tripropylamine (TPA), but also can demonstrate the interaction between the co-existing emitters. It is shown that the ECL from both Ru(bpy)32+and TPA of the Ru(bpy)32+/TPA system can be mutually promoted in electrochemical potential and in a concentration-dependent way. The self-ECL of TPA at the potential of 1.24 V can be enhanced from 4.9- to 51-fold with the Ru(bpy)32+concentration increasing from 0.01 to 0.8 mu M. In the presence of 0.04 mu M Ru(bpy)32+, the self-ECL of TPA is enhanced by 94- and 10.2-fold at the potential of 1.01 and 1.76 V, respectively. The portable inexpensive BPF turntable device is also useful in spectrum-resolved multi-analyte determination and ratiometric ECL biosensors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据