Detection of Volatile Toxic Industrial Chemicals with Classical Ion Mobility Spectrometry and High-Kinetic Energy Ion Mobility Spectrometry

期刊

ANALYTICAL CHEMISTRY
卷 94, 期 2, 页码 1211-1220

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c04397

关键词

-

向作者/读者索取更多资源

This study evaluates the capabilities and limitations of high-kinetic energy IMS (HiKE-IMS) in on-site detection of toxic industrial chemicals (TICs). The results show that HiKE-IMS has lower sensitivity compared to classical IMS, but the reduced sensitivity is not a major drawback for TIC detection. The achievable limits of detection for most TICs are below the safety levels, and HiKE-IMS exhibits significantly lower false-positive and false-negative rates compared to classical IMS.
Due to their high sensitivity and compact design, ion mobility spectrometers are widely used to detect toxic industrial chemicals (TICs) in air. However, when analyzing complex gas mixtures, classical ion mobility spectrometry (IMS) suffers from false-positive rates due to limited resolving power or false-negative rates caused by competitive ion-molecule reactions and the resulting suppression of certain analyte ions. To overcome these limitations, high-kinetic energy IMS (HiKE-IMS) was introduced some years ago. In contrast to classical IMS, HiKE-IMS is operated at decreased pressures of 20 center dot center dot center dot 60 mbar and high reduced electric field strengths E/N of up to 120 Td. Under these conditions, the influence of competitive ion-molecule reactions on the prevailing ion population should be less pronounced, thus reducing false negatives. Additionally, effects such as fragmentation and field-dependent ion mobility may help to reduce false positives. In this work, the capabilities and limitations of HiKE-IMS in the field of on-site detection of the volatile TICs NH3, HCN, H2S, HCl, NO2, Cl-2, and SO2 are evaluated for the first time. Based on the limits of detection and the extent of spectral and chemical cross-sensitivities in gas mixtures, the results obtained for HiKE-IMS are compared with those obtained for classical IMS. It is shown that HiKE-IMS is less sensitive in comparison to classical IMS. However, when used for TIC detection, the reduced sensitivity of HiKE-IMS is not a major drawback. With values around 1 ppm(v), the achievable limits of detection for almost all TICs are below the AEGL-2 (4h) levels. Furthermore, in comparison to classical IMS, it is still striking that HiKE-IMS shows significantly less spectral and chemical cross-sensitivities and thus exhibits considerably lower false-positive and false-negative rates. Overall, it thus turns out that HiKE-IMS is a promising alternative to classical IMS in the field of on-site detection of TICs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据