4.8 Article

Conductive Covalent Organic Frameworks with Conductivity- and Pre-Reduction-Enhanced Electrochemiluminescence for Ultrasensitive Biosensor Construction

期刊

ANALYTICAL CHEMISTRY
卷 94, 期 8, 页码 3685-3692

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c05436

关键词

-

资金

  1. NSFC [21571149]
  2. Innovation Support Program for Chongqing Overseas Returnees [cx2017007, cx2018026]

向作者/读者索取更多资源

The study focuses on improving the electrochemiluminescence (ECL) performance of covalent organic frameworks (COFs) by enhancing conductivity and pre-reduction, and applying them to ultrasensitive biosensor detection systems.
Covalent organic frameworks (COFs) have attracted widespread attention in the electrochemiluminescence (ECL) field owing to their high load capacity of ECL luminophores and porous structures, but their ECL performance is still limited by the intrinsic poor conductivity (generally <10(-8) S m(-1)). To address this shortcoming, we used 2,3,6,7,10,11-hexaaminotriphenylene (HATP) and 2,3,6,7,10,11-hexahydroxytriphenylene (HHTP) to synthesize a conductive COF (HHTP-HATP-COF, conductivity = 3.11 x 10(-4) S m(-1)). Compared with HATP, HHTP, and low-conductive HHTP-DABZ-COF, HHTP-HATP-COF exhibited superior ECL perform-ance, not only because HHTP-HATP-COF possessed massive ECL luminophores but also because its conductive porous framework accelerated charge transport in the whole framework and improved the utilization ratio of ECL luminophores. More interestingly, the ECL intensity of the HHTP-HATP-COF/S2O82- system was further improved after pre-reduction electrolysis due to the accumulation of HHTP-HATP-COF cation radicals. The experimental results showed that the ECL intensity of the HHTP-HATP-COF/S2O82- system after pre-reduction was about 1.64-, 3.96-, 6.88-, and 8.09-fold higher than those of HHTP-HATP-COF/ S2O82-, HHTP-DABZ-COF/S2O82-, HHTP/S2O82-, and HATP/S2O82- systems, respectively. Considering the superior ECL property of the HHTP-HATP-COF/S2O82- system after pre-reduction, it was used as a high-efficient ECL beacon together with an aptamer/protein proximity binding-induced three-dimensional bipedal DNA walker to construct an ultrasensitive biosensor for thrombin detection, which displayed broad linearity (100 aM to 1 nM) with a detection limit of 62.1 aM. Overall, the work offered effective ways to increase ECL performance by the enhancement of conductivity and by the pre-reduction, proposing new ideas to design high-efficiency COF-based ECL materials and endowing conductive COFs with ECL biosensor application for the first time.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据