4.7 Article

Colorimetric paper-based sarcosine assay with improved sensitivity

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 414, 期 1, 页码 691-701

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03682-0

关键词

Artificial urine; Prostate cancer biomarker; Sarcosine oxidase; Cationically charged polyamine; Hydrogen peroxide; Enzymatic sarcosine assay

向作者/读者索取更多资源

This study presents a paper-based bienzymatic colorimetric assay for detecting sarcosine, an important urinary biomarker of prostate cancer, achieving a lower limit of detection and higher selectivity. The presence of polymer was found to restrict the enzyme-driven colorimetric reaction, leading to stronger color development.
This manuscript reports on a simple paper-based bienzymatic colorimetric assay for sarcosine as an important urinary biomarker of prostate cancer. All required assay reagents are pre-deposited on hydrophilic filter paper spots surrounded by a hydrophobic barrier. Sarcosine in the sample solution is selectively oxidized in the presence of sarcosine oxidase (SOx), resulting in the formation of hydrogen peroxide, which is subsequently detected through the horseradish peroxidase (HRP)-catalyzed conversion of the colorless indicator 3,3',5,5'-tetramethylbenzidine (TMB) into its blue-colored oxidation product. By the modification of the paper with positively charged poly(allylamine hydrochloride) (PAH), a linear response to sarcosine between 0 and 10 mu M and a significant lowering of the limit of detection (LOD) (0.6 mu M) compared to the unmodified paper substrate (12.6 mu M) has been achieved. The improvement of the LOD was attributed to the fact that the presence of the polymer limits the enzyme-driven colorimetric reaction to the surface of the paper substrate, resulting in stronger color development. In experiments in artificial urine matrix, the bicarbonate anion was identified as an inhibitor of the colorimetric reaction. This inhibition was successfully eliminated through on-device sample pH adjustments with pH-buffer components pre-deposited onto assay devices. The LOD for sarcosine achieved in artificial urine matrix (2.5 mu M) is below the 5 mu M threshold value for this urinary biomarker required for diagnostic purposes. Finally, good selectivity over all 20 natural amino acids and satisfactory long-term storage stability of reagent-modified paper substrates at - 20 degrees C for a period of 50 days were confirmed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据