4.7 Article

Highly sensitive interleukin 6 detection by employing commercially ready liposomes in an LFA format

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 414, 期 10, 页码 3231-3241

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03750-5

关键词

Lateral flow assay; Point-of-care diagnostics; Bioanalysis; Fluorescence liposomes; Colloidal gold; Interleukin 6

资金

  1. Central Innovation Program for small-and medium-sized enterprises (SMEs) by the Federal Ministry of Economic Affairs and Energy
  2. Microcoat Biotechnology (Germany)

向作者/读者索取更多资源

This study demonstrates the use of liposomes to improve the LOD of traditional gold nanoparticle-based assays while maintaining ease of use. Liposomes outperform AuNPs in photometric LFAs, especially in complex matrices like human serum. The technology shows great potential for improving detection of low abundance analytes such as IL-6.
Recent years have confirmed the ubiquitous applicability of lateral flow assays (LFA) in point-of-care testing (POCT). To make this technology available for low abundance analytes, strategies towards lower limits of detections (LOD), while maintaining the LFA's ease of use, are still being sought. Here, we demonstrate how liposomes can significantly improve the LOD of traditional gold nanoparticle (AuNP)-based assays while fully supporting a ready-to-use system for commercial application. We fine-tuned liposomes towards photometric and fluorescence performance on the synthesis level and applied them in an established interleukin 6 (IL-6) immunoassay normally using commercial AuNP labels. IL-6's low abundance (< 10 pg mL(-1)) and increasing relevance as prognostic marker for infections make it an ideal model analyte. It was found that liposomes with a high encapsulant load (150 mmol L-1 sulforhodamine B (SRB)) easily outperform AuNPs in photometric LFAs. Specifically, liposomes with 350 nm in diameter yield a lower LOD even in complex matrices such as human serum below the clinically relevant range (7 pg mL(-1)) beating AuNP by over an order of magnitude (81 pg mL(-1)). When dehydrated on the strip, liposomes maintained their signal performance for over a year even when stored at ambient temperature and indicate extraordinary stability of up to 8 years when stored as liquid. Whereas no LOD improvement was obtained by exploiting the liposomes' fluorescence, an extraordinary gain in signal intensity was achieved upon lysis which is a promising feature for high-resolution and low-cost detection devices. Minimizing the procedural steps by inherently fluorescent liposomes, however, is not feasible. Finally, liposomes are ready for commercial applications as they are easy to mass-produce and can simply be substituted for the ubiquitously used AuNPs in the POCT market.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据