4.7 Article

A fluorescent sensor recognized by the FA1 site for highly sensitive detection of HSA

期刊

ANALYTICA CHIMICA ACTA
卷 1188, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2021.339201

关键词

HSA; Fluorescent sensor; FA1 site; Human urine; Cell culture medium

资金

  1. National Natural Science Foundation of China [32000910]
  2. Fundamental Research Funds for the Central Universities [lzujbky-2021-47, lzujbky-2021-kb19]

向作者/读者索取更多资源

A selective light-up fluorescent sensor DCM-ML was successfully developed for quantification of HSA, exhibiting good stability and strong fluorescence enhancement. The sensor showed a linear relationship with HSA concentration and a detection limit of 0.25 mg/mL, suggesting great potential in analytical chemistry and clinical medicine.
Human serum albumin (HSA), as the most abundant protein in blood plasma, plays a crucial role in many physiological processes. The abnormal HSA level in serum or in urine is often associated with various diseases. Therefore, to achieve highly sensitive and selective quantification of HSA is of great importance for disease diagnosis and preventive medicine. Herein, an HSA-selective light-up fluorescent sensor, DCM-ML, was successfully developed for quantitative detection of HSA. DCM-ML exhibited good (photo-) stability and strong fluorescence enhancement around 630 nm in the presence of HSA in complex samples containing numerous biological analytes. Upon addition of HSA into DCM-ML containing solution, a good linear relationship (R-2 > 0.99) between the fluorescence intensity of DCM-ML and HSA concentration from 0 to 0.08 mg/mL was obtained with the detection limit of 0.25 mg/mL. The sensing mechanism of the sensor towards HSA was demonstrated to be via recognition in the fatty acid site 1 (FA1), instead of the most reported binding sites (Sudlow I and II) in HSA, for the first time, by both the displacement experiments and molecular docking simulation. Thus, DCM-ML can also be assumed as a potential FA1 site-binding marker for examining drugs binding to the FA1 site in HSA. At last, the utilization of sensor DCM-ML for quantification and validation of HSA in urine samples and cell culture medium was effectively demonstrated. Therefore, the development of DCM-ML should find great application potentials in the fields of analytical chemistry and clinical medicine as a highly sensitive HSA sensor. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据