4.7 Article

Measuring evaporation rate constants of highly volatile compounds for use in predictive kinetic models

期刊

ANALYTICA CHIMICA ACTA
卷 1182, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2021.338932

关键词

Kinetic model; Evaporation; Ignitable liquid; Volatile compounds; Gas chromatography-mass spectrometry

资金

  1. National Institute of Justice Award [2018-DU-BX-0225]

向作者/读者索取更多资源

A kinetic model was developed to predict evaporation of compounds based on gas chromatographic retention index. Experimental determination of rate constants for highly volatile compounds allowed for extension of the model's applicability range with successful validation through comparison of predicted and experimental chromatograms.
A kinetic model was previously developed in our laboratory to predict evaporation of compounds as a function of gas chromatographic retention index (I-T). To define the initial model, evaporation rate constants were experimentally determined for compounds in the range I-T = 800-1400 at temperatures from 5 to 35 degrees C. While the predictive accuracy was demonstrated, broader application of the model requires extension of the IT range to include more volatile compounds. However, such extension requires experimental determination of rate constants, which is challenging due to the explosive hazard and rapid evaporation of volatile compounds. In this work, rate constants of highly volatile compounds were experimentally determined and used to extend the kinetic model to predict evaporation. Prior to experimental evaporations, theoretical calculations were performed to optimize experimental parameters and to ensure that the vapor generated remained below the lower flammability limit for each compound. Compounds were then experimentally evaporated at three different temperatures (10, 20, and 30 degrees C) and analyzed by gas chromatography-mass spectrometry. The evaporation rate constants for each compound, corrected for condensation, were determined by regression to a first-order rate equation. These rate constants were combined with previously collected data to extend the kinetic model at each temperature. Comparison of predicted and experimentally determined chromatograms of an evaporated validation mixture indicated good model performance, with correlation coefficients ranging from 0.955 to 0.997 and mean absolute percent errors in predicting abundance ranging from 3 to 26%. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据