4.7 Article

Silver(I)-selective impedimetric and potentiometric detection at 3-hydroxy-N-(4-mercaptophenyl)benzamide functionalized gold surface - Analysis of water and packaged food products

期刊

ANALYTICA CHIMICA ACTA
卷 1192, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2021.339349

关键词

Silver; Self-assembly; Electrochemical impedance spectroscopy; Cyclic voltammetry; Carbon paste electrode (CPE)

资金

  1. Science & Engineering Research Board, Department of Science and Technology (SERB-DST), New Delhi [SB/FT/CS-057/2014]
  2. Ministry of Human Resources Development, Government of India under RUSA 2.0 Programme
  3. University Grant Commission, New Delhi

向作者/读者索取更多资源

In this study, a monothiol HMB was synthesized and self-assembled on a gold electrode surface. The HMB-modified electrode showed excellent sensitivity towards silver ions with a wide linear range and low detection limit. Additionally, HMB-modified gold nanoparticles were used to construct a carbon paste electrode for potentiometric detection of silver ions.
In the current work, a monothiol, 3-hydroxy-N-(4-mercaptophenyl) benzamide (HMB) was synthesized via amide coupling of 4-aminothiophenol with 3-hydroxybenzoic acid followed by its self-assembly on the surface of a gold electrode which was confirmed using electrochemical techniques: cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) and spectroscopic techniques: AFM and FT-IR. Further, HMB functionalized gold electrode (HMB-Au) was utilised as a platform for impedimetric sensing in the presence of one-electron reversible redox probe, [Fe(CN)(6)](3-/4-) and found to show sensitivity towards Ag+ over a wide linear concentration range from 1 x 10(-9) M to 1 x 10(-4) M (r(2) = 0.99 +/- 0.005) at pH = 8 with a detection limit of 3.60 x 10(-9) M. Furthermore, HMB self-assembled Au nanoparticles (HMB-AuNPs) were incorporated as modifier to construct a carbon paste electrode (CPE) for potentiometric detection of Ag+. Ag+-CPE exhibited a Nernstian slope of 61.70 +/- 0.02 mV per decade in the concentration range of 1.0 x 10(-4) M - 1.0 x 10(-1) M (r(2) = 0.99 +/- 0.01) with a detection limit of 4.46 x 10(-5) M and a short response time of 15 s. Both HMB based EIS sensor and CPE have shown an acceptable selectivity towards silver(I) ions and successfully applied for estimation of silver(I) content in various samples of water and packaged food products. (c) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。