4.6 Article

Retroreflection-based sandwich type affinity sensing of isothermal gene amplification products for foodborne pathogen detection

期刊

ANALYST
卷 147, 期 3, 页码 450-460

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1an01543e

关键词

-

资金

  1. Creative Materials Discovery Program [NRF-2019M3D1A1078943, NRF-2019R1A6A1A11051471, NRF-2021R1A2C3004180]
  2. National Research Foundation of Korea
  3. Technology Innovation Program [20004103]
  4. MOTIE, Korea

向作者/读者索取更多资源

Loop-mediated isothermal amplification (LAMP) is a rapid, specific, and sensitive method for molecular diagnostics, although it requires a sophisticated optical setup. This study developed a novel sensing method that can quantify target analytes using simple equipment, successfully applied to quantitative analysis of Salmonella. The results suggest the potential application of this method in pathogen detection in contaminated food sources.
Loop-mediated isothermal amplification (LAMP) is an outstanding method for molecular diagnostics, as the rapid, specific, and sensitive amplification of target genes is possible. However, it is necessary to measure fluorescence in the quantitative analysis of LAMP products, so a sophisticated optical setup is required. This study tried to develop a novel sensing method that can quantify target analytes with simple equipment, such as nonspectroscopic white light and a CMOS camera. To achieve this, a retroreflective Janus particle (RJP) as a probe and specially designed loop primers, fluorescein isothiocyanate (FITC)- and biotin-modified loop primers, were introduced into the LAMP system. By performing LAMP in the presence of designed primers, double-stranded amplicons possessing FITC and biotin labels at each end are generated in proportion to the quantity of the target pathogen. Using the anti-FITC antibody-modified sensing surface and streptavidin-conjugated RJP probes, the amplicons can be captured in sandwich-configuration and detected under nonspectroscopic conditions composed of white light and a camera. To confirm the feasibility of the sensing system, the invA gene of Salmonella was selected as the target. It was possible to quantitatively analyze the Salmonella concentration from 0 to 10(6) colony-forming units, sufficiently covering the required detection range. In addition, quantitative analyses of pathogens in contaminated food sources, including milk and chicken meat, were successfully conducted with a limit of detection of 10 CFU.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据