4.6 Article

Measurement Error Affecting Web- and Paper-Based Dietary Assessment Instruments: Insights from the Multi-Cohort Eating and Activity Study for Understanding Reporting Error

期刊

AMERICAN JOURNAL OF EPIDEMIOLOGY
卷 191, 期 6, 页码 1125-1139

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/aje/kwac026

关键词

24-hour recall; dietary assessment; food frequency questionnaire; food record; recovery biomarkers; validation

资金

  1. National Cancer Institute [HHSN261201000087I, HHSN26100003, N02-PC-64406]
  2. National Institute on Alcohol Abuse and Alcoholism [RR020915]
  3. National Institutes of Health [UM1-CA186107, UM1-CA176726, UM1-CA167552, P01-CA055075-18S1, U01-CA152904]

向作者/读者索取更多资源

This study examined the measurement error of different dietary assessment instruments and found that they have varying attenuation factors and correlation coefficients. The findings support prior research suggesting that different instruments have unique strengths that should be leveraged in epidemiologic research.
Few biomarker-based validation studies have examined error in online self-report dietary assessment instruments, and food records (FRs) have been considered less than food frequency questionnaires (FFQs) and 24-hour recalls (24HRs). We investigated measurement error in online and paper-based FFQs, online 24HRs, and paper-based FRs in 3 samples drawn primarily from 3 cohorts, comprising 1,393 women and 1,455 men aged 45-86 years. Data collection occurred from January 2011 to October 2013. Attenuation factors and correlation coefficients between reported and true usual intake for energy, protein, sodium, potassium, and respective densities were estimated using recovery biomarkers. Across studies, average attenuation factors for energy were 0.07, 0.07, and 0.19 for a single FFQ, 24HR, and FR, respectively. Correlation coefficients for energy were 0.24, 0.23, and 0.40, respectively. Excluding energy, the average attenuation factors across nutrients and studies were 0.22 for a single FFQ, 0.22 for a single 24HR, and 0.51 for a single FR. Corresponding correlation coefficients were 0.31, 0.34, and 0.53, respectively. For densities (nutrient expressed relative to energy), the average attenuation factors across studies were 0.37, 0.17, and 0.50, respectively. The findings support prior research suggesting different instruments have unique strengths that should be leveraged in epidemiologic research.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据