4.5 Article

Empirical evidence for safety of mechanical ventilation during simulated cardiopulmonary resuscitation on a physical model

期刊

AMERICAN JOURNAL OF EMERGENCY MEDICINE
卷 48, 期 -, 页码 312-315

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.ajem.2021.06.062

关键词

Cardiopulmonary resuscitation; Mechanical ventilation; Cardiac arrest; Simulation

资金

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)
  2. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)
  3. Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ)

向作者/读者索取更多资源

This study assessed the response of mechanical ventilation to CPR, showing that different ventilation modes have slight variations in response to chest compressions, but the delivered volume and peak pressures were within the range observed during bag-valve-mask ventilation.
Background: Cardiac arrest is a critical event requiring adequate and timely response in order to increase a patient's chance of survival. In patients mechanically ventilated with advanced airways, cardiopulmonary resus-citation (CPR) maneuver may be simplified by keeping the ventilator on. This work assessed the response of an intensive care mechanical ventilator to CPR using a patient manikin ventilated in three conventional modes. Methods: Volume-controlled (VCV), pressure-controlled (PCV) and pressure regulated volume-controlled (PRVC) ventilation were applied in a thorax physical model, with or without chest compressions. The mechanical ventilator was set with inspiratory time of 1.0 s, ventilation rate of 10 breaths/min, positive end-expiratory pres-sure of 0 cmH(2)O, FiO(2) of 1.0, target tidal volume of 600 mL and trigger level of -20 cmH(2)O. Airway opening pres-sure and ventilatory flow signals were continuously recorded. Results: Chest compression resulted in increased airway peak pressure in all ventilation modes (p < 0.001), espe-cially with VCV (137% in VCV, 83% in PCV, 80% in PRVC). However, these pressures were limited to levels similar to release valves in manual resuscitators (similar to 60 cmH(2)O). In pressure-controlled modes tidal/min volumes de-creased (PRVC = 11%, p = 0.027 and PCV = 12%, p < 0.001), while still within the variability observed during bag-valve-mask ventilation. During VCV, variation in tidal/min volumes were not significant (p = 0.140). Respi-ratory rate did not change with chest compression. Conclusions: Volume and pressure ventilation modes responded differently to chest compressions. Yet, variation in delivered volume and the measured peak pressures were within the reported for the standard bag-valve-mask system. (C) 2021 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据