4.8 Article

Evaluation of the Adsorption-Accessible Surface Area of MIL-53(Al) using Cannabinoids in a Closed System

期刊

ACS APPLIED MATERIALS & INTERFACES
卷 14, 期 10, 页码 12836-12844

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsami.1c24391

关键词

cannabinoids; metal-organic frameworks; MIL-53(Al); high performanceliquid chromatography; mass spectrometry; solvent-accessible surface area

资金

  1. Panacea Life Sciences Cannabinoid Research Center

向作者/读者索取更多资源

In this study, the suitability of a commercially available metal-organic framework (MOF) called MIL-53(Al) as a stationary phase for cannabinoid separations was evaluated. The results showed that most of the MOF surface area was inaccessible for adsorption by cannabinoids due to size-exclusion effects. This study suggests that MOFs may have an upper limit for the size of the analyte and may be more suitable for separations in the gas phase.
Cannabinoids are important industrial analytes commonly assayed with high-pressure liquid chromatography (HPLC). In this study, we evaluate the suitability of MIL-53(Al), a commercially available metal-organic framework (MOF), as a stationary phase for cannabinoid separations. The suitability of an MOF for a given separation is hypothesized to be limited by the ability of a given molecule to enter the pore of the MOF. To evaluate the extent of possible adsorptive interactions between cannabinoids and the interior surface area of MIL-53(Al), the radii of gyration (R-g) and solvent-accessible surface areas were calculated for three cannabinoids, namely, cannabidiol, cannabinol, and Delta 9-tetrahydrocannabinol, as well as the MOF. These values were used to calculate the theoretical adsorption capacity of the MOF, using four competing adsorption models. The R-g of cannabinoids (4.1 angstrom) is larger than one MOF pore aperture dimension (4.0 x 5.0 angstrom). The adsorption capacity was measured by relating a decrease in the cannabinoid concentration in acetonitrile when exposed to 100 mg of MOF. The cannabinoid uptake by the MOF was estimated using the relative standard deviation (RSD) of the soaking solution assay, as the decomposition-corrected RSD as uptake (DCRU). The DCRU was calculated as 0.007 +/- 0.004 mu g(cannabinoids)/mg(MOF). These findings indicate that most of the MOF surface area was inaccessible for adsorption by cannabinoids due to size-exclusion effects. The implication of this work is that the suitability of an MOF for adsorptive separations, such as liquid chromatography, must have an upper limit for the size of the analyte. Additionally, MOFs may generally be more suitable for separations in the gas phase, where adsorbates are not hindered by the presence of a solvation shell.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据