4.8 Article

Low-Cost Flexible Glass-Based pH Sensor via Cold Atmospheric Plasma Deposition

期刊

ACS APPLIED MATERIALS & INTERFACES
卷 14, 期 7, 页码 9697-9710

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsami.1c19805

关键词

pH sensor; silica coating; cold atmospheric pressure plasma; all-printed electrochemical sensors

资金

  1. SMART Films Consortium at Birck Nanotechnology Center, Purdue University
  2. School of Material Engineering at Purdue University

向作者/读者索取更多资源

This paper presents the fabrication of a flexible glass-based pH sensor suitable for biomedical and environmental applications. The sensor was fabricated using the cold atmospheric plasma technique and a pH sensitive silica coating was deposited onto a carbon electrode. The sensitivity and stability of the sensor were improved through a postprocessing step.
Many commercially available pH sensors are fabricated with a glass membrane as the sensing component because of several advantages of glass-based electrodes such as versatility, high accuracy, and excellent stability in various conditions. However, because of their bulkiness and poor mechanical properties, conventional glass-based sensors are not ideal for wearable or flexible applications. Here, we report for the first time the fabrication of a flexible glass-based pH sensor suitable for biomedical and environmental applications where flexibility and stability of the sensor are critical for long-term and real-time monitoring. The sensor was fabricated via a simple and facile approach using the cold atmospheric plasma technique in which a pH sensitive silica coating was deposited from a siloxane precursor onto a carbon electrode. In order to increase the sensitivity and stability of the sensor, we employed a postprocessing step which involves annealing of the silica coated electrode at elevated temperatures. This process was optimized to ensure that the crucial properties such as porosity and hydration functionality were balanced to obtain the best and most reliable sensitivity of the sensor. Our sensitivity test results indicated that these sensors exhibit excellent and stable sensitivity with a slope of about 48 mV/pH (r(2) = 0.998) and selectivity across a pH range of 4 to 10 in the presence of various cations. The optimized sensor has shown stable sensitivity for a long period of time (30 h of immersion) and in different bending conditions. We demonstrate in this investigation that this flexible cost-effective pH sensor can withstand the sterilization process resulting from ultraviolet radiation and shows repeatable sensitivity with less than +/- 5 mV potential drift from the sensitivity values of the standard optimized sensor.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论