4.6 Review

Complex Relationship Between Artificial Intelligence and CT Radiation Dose

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Real-World Surveillance of FDA-Cleared Artificial Intelligence Models: Rationale and Logistics

Keith J. Dreyer et al.

JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY (2022)

Article Computer Science, Artificial Intelligence

Deep learning for biomedical image reconstruction: a survey

Hanene Ben Yedder et al.

Summary: Medical imaging is essential in medicine, providing valuable information for disease diagnosis and treatment. Reconstruction algorithms play a crucial role in transforming signals into interpretable images, with a focus on reducing radiation exposure and increasing reconstruction accuracy. Deep learning presents a promising approach for image reconstruction, offering artifact reduction and speed-up with automatic feature extraction.

ARTIFICIAL INTELLIGENCE REVIEW (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

A study of using a deep learning image reconstruction to improve the image quality of extremely low-dose contrast-enhanced abdominal CT for patients with hepatic lesions

Le Cao et al.

Summary: The study demonstrates that deep learning image reconstruction can significantly reduce radiation dose and improve image quality in abdominal CT. Particularly in low-dose conditions, DLIR-H generates images with lower noise and higher overall image quality.

BRITISH JOURNAL OF RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Diagnostic value of deep learning reconstruction for radiation dose reduction at abdominal ultra-high-resolution CT

Yuko Nakamura et al.

Summary: In this study, lower dose hepatic dynamic U-HRCT images reconstructed with DLR and MBIR were found to be superior to standard dose images reconstructed with hybrid-IR in both hepatic arterial and equilibrium phases. Only DLR images were found to be superior in terms of image quality scores.

EUROPEAN RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Effect of obesity on ability to lower exposure for detection of low-attenuation liver lesions

Brian R. Herts et al.

Summary: The study found that obesity has a negative impact on the accuracy of liver lesion detection, with accuracy decreasing faster during exposure reduction. There were no significant differences in lesion detection between FBP and ADMIRE at different exposure levels.

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Rapid measurement of the low contrast detectability of CT scanners

Akinyinka Omigbodun et al.

Summary: A new framework for objectively characterizing low contrast detectability (LCD) in computed tomography (CT) imaging was introduced, producing a machine LCD metric with more representative results. Experimental scans demonstrated the feasibility of the technique in measuring machine LCD with tight error bars using only a single scan, which could facilitate routine quality assurance and comparisons between different protocols and scanners.

MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction

Samuel L. Brady et al.

Summary: A study compared different reconstruction algorithms in pediatric CT, finding that the DLR algorithm showed better object detectability and image quality compared to other algorithms, with a more significant dose reduction.

RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality

Angelique Bernard et al.

Summary: In a study of 296 patients, the use of a DLR algorithm for cardiac CCTA in an acute stroke imaging protocol significantly reduced radiation dose and improved image quality compared to an iterative reconstruction algorithm.

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep learning trained algorithm maintains the quality of half-dose contrast-enhanced liver computed tomography images: Comparison with hybrid iterative reconstruction Study for the application of deep learning noise reduction technology in low dose

Lingming Zeng et al.

Summary: The study found that using DELTA for half-dose contrast-enhanced liver CT scans can significantly reduce dosage by approximately 49% compared to using HIR for standard-dose CT, while maintaining image quality.

EUROPEAN JOURNAL OF RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Reproducibility of lung nodule radiomic features: Multivariable and univariable investigations that account for interactions between CT acquisition and reconstruction parameters

Nastaran Emaminejad et al.

Summary: This study systematically explored the impact of CT parameters on lung nodule radiomic features. The majority of radiomic features lacked reproducibility, and interactions among CT parameters were revealed, indicating that the effect of individual CT parameters on radiomic features may be dependent on other CT acquisition and reconstruction parameters.

MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Radiomics in the evaluation of lung nodules: Intrapatient concordance between full-dose and ultra-low-dose chest computed tomography

Pierre-Alexis Autrusseau et al.

Summary: The study aimed to evaluate the agreement of pulmonary nodule risk assessment by radiomics software between full-dose and ultra-low-dose chest CT. The results demonstrated good agreement between the two CT doses in assessing the malignancy similarity index of lung nodules.

DIAGNOSTIC AND INTERVENTIONAL IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

A comparison between manual and artificial intelligence-based automatic positioning in CT imaging for COVID-19 patients

Yadong Gang et al.

Summary: The study compared the imaging workflow, radiation dose, and image quality of COVID-19 patients between conventional manual positioning (MP) and AI-based automatic positioning (AP) methods. The results showed that the AP method reduced positioning time, radiation dose, and improved image quality compared to the MP method, making it a promising technique for optimizing chest imaging.

EUROPEAN RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Sinogram-based deep learning image reconstruction technique in abdominal CT: image quality considerations

Anushri Parakh et al.

Summary: The sinogram-based deep learning image reconstructions were both subjectively and objectively preferred over iterative reconstruction due to improved image quality and lower noise, even in large patients. DLIR-H had the best objective scores, indicating potential for clinical use and radiation dose reduction.

EUROPEAN RADIOLOGY (2021)

Article Medicine, General & Internal

The potential for reduced radiation dose from deep learning-based CT image reconstruction A comparison with filtered back projection and hybrid iterative reconstruction using a phantom

Ji Eun Lee et al.

Summary: This phantom study compares radiation dose and image quality of abdominal CT scanned with different tube voltages and tube currents under different reconstruction algorithms. It found that DLIR algorithms can reduce radiation dose by 65.5% to 68.1% while maintaining comparable image quality. Furthermore, medium strength DLIR algorithm can even improve image quality with a reduced radiation dose of 36.2% to 50.0% compared to the reference image.

MEDICINE (2021)

Editorial Material Biochemistry & Molecular Biology

How medical AI devices are evaluated: limitations and recommendations from an analysis of FDA approvals

Eric Wu et al.

Summary: A comprehensive overview of medical AI devices approved by the US Food and Drug Administration sheds light on limitations of the evaluation process that may mask vulnerabilities of devices when deployed on patients.

NATURE MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of image quality and lesion diagnosis in abdominopelvic unenhanced CT between reduced-dose CT using deep learning post-processing and standard-dose CT using iterative reconstruction: A prospective study

Xiao Wang et al.

Summary: This study compared image quality and lesion diagnosis between reduced-dose CT with DL post-processing and standard-dose CT with iterative reconstruction. The results showed that reduced-dose CT combined with DL post-processing can ensure image quality and satisfy diagnostic needs, with a significant reduction in radiation dose.

EUROPEAN JOURNAL OF RADIOLOGY (2021)

Article Engineering, Electrical & Electronic

SPECIAL: Single-Shot Projection Error Correction Integrated Adversarial Learning for Limited-Angle CT

Dianlin Hu et al.

Summary: The proposed SPECIAL method in this paper effectively combines information in both the image and projection domains to greatly improve reconstructions in limited-angle CT, particularly in artifact removal, edge preservation, and tiny structure restoration. Enhanced adversarial learning and projection error correction modules are utilized to achieve the promising improvement compared to other competitive algorithms.

IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING (2021)

Article Engineering, Electrical & Electronic

CD-Net: Comprehensive Domain Network With Spectral Complementary for DECT Sparse-View Reconstruction

Yikun Zhang et al.

Summary: Dual-energy computed tomography (DECT) is clinically significant for material identification, and the proposed CD-Net utilizes spectral complementarity to improve image quality and reduce radiation dose. CD-Net includes a projection domain neural network, an analytical reconstruction operator, and an image domain neural network to restore accurate anatomical information.

IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING (2021)

Article Computer Science, Artificial Intelligence

Common pitfalls and recommendations for using machine learning to detect and prognosticate for COVID-19 using chest radiographs and CT scans

Michael Roberts et al.

Summary: Many machine learning-based approaches have been developed for the prognosis and diagnosis of COVID-19 from medical images. However, a systematic review found that current studies have methodological flaws, preventing their potential clinical utility. Recommendations are provided to address these issues for higher-quality model development.

NATURE MACHINE INTELLIGENCE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise

Joo Hee Kim et al.

Summary: This study evaluated image quality and noise of LDCT scan images reconstructed with DLIR and compared with those of images reconstructed with ASiR-V 30%. Results showed that DLIR significantly reduced image noise while maintaining superior image quality, outperforming ASiR-V 30%.

KOREAN JOURNAL OF RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep Learning Reconstruction at CT: Phantom Study of the Image Characteristics

Toru Higaki et al.

ACADEMIC RADIOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Image Quality and Lesion Detection on Deep Learning Reconstruction and Iterative Reconstruction of Submillisievert Chest and Abdominal CT

Ramandeep Singh et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study

Joel Greffier et al.

EUROPEAN RADIOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial Experience

Corey T. Jensen et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2020)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Artificial Intelligence and CT Image Reconstruction: Potential of a New Era in Radiation Dose Reduction

Avinash Kambadakone

JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY (2020)

Article Computer Science, Interdisciplinary Applications

A 3D Probabilistic Deep Learning System for Detection and Diagnosis of Lung Cancer Using Low-Dose CT Scans

Onur Ozdemir et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2020)

Review Radiology, Nuclear Medicine & Medical Imaging

Artificial Intelligence in Diagnostic Imaging Status Quo, Challenges, and Future Opportunities

Puneet Sharma et al.

JOURNAL OF THORACIC IMAGING (2020)

Article Oncology

DeepLN: an artificial intelligence-based automated system for lung cancer screening

Jixiang Guo et al.

ANNALS OF TRANSLATIONAL MEDICINE (2020)

Review Radiology, Nuclear Medicine & Medical Imaging

The use of artificial intelligence in computed tomography image reconstruction - A literature review

Ziyu Zhang et al.

JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES (2020)

Review Computer Science, Artificial Intelligence

Deep learning for tomographic image reconstruction

Ge Wang et al.

NATURE MACHINE INTELLIGENCE (2020)

Review Radiology, Nuclear Medicine & Medical Imaging

Artificial intelligence in image reconstruction: The change is here

Ramandeep Singh et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2020)

Article Engineering, Biomedical

A deep learning approach to radiation dose estimation

Th Goetz et al.

PHYSICS IN MEDICINE AND BIOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Potential of a machine-learning model for dose optimization in CT quality assurance

Axel Meineke et al.

EUROPEAN RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CT

Corey T. Jensen et al.

RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT

Motonori Akagi et al.

EUROPEAN RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Analysis of a CT patient dose database with an unsupervised clustering approach

O. Rampado et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Imaging Quality Control in the Era of Artificial Intelligence

David B. Larson et al.

JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Accuracy of automated patient positioning in CT using a 3D camera for body contour detection

Ronald Booij et al.

EUROPEAN RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

The evolution of image reconstruction for CTfrom filtered back projection to artificial intelligence

Martin J. Willemink et al.

EUROPEAN RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Potential value of the PixelShine deep learning algorithm for increasing quality of 70 kVp+ASiR-V reconstruction pelvic arterial phase CT images

Shi-feng Tian et al.

JAPANESE JOURNAL OF RADIOLOGY (2019)

Article Computer Science, Interdisciplinary Applications

Domain Progressive 3D Residual Convolution Network to Improve Low-Dose CT Imaging

Xiangrui Yin et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2019)

Review Computer Science, Artificial Intelligence

Generative adversarial network in medical imaging: A review

Xin Yi et al.

MEDICAL IMAGE ANALYSIS (2019)

Article Computer Science, Artificial Intelligence

Competitive performance of a modularized deep neural network compared to commercial algorithms for low-dose CT image reconstruction

Hongming Shan et al.

NATURE MACHINE INTELLIGENCE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Application of Vendor-Neutral Iterative Reconstruction Technique to Pediatric Abdominal Computed Tomography

Woo Hyeon Lim et al.

KOREAN JOURNAL OF RADIOLOGY (2019)

Editorial Material Computer Science, Interdisciplinary Applications

Image Reconstruction Is a New Frontier of Machine Learning

Ge Wang et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Precise and Automatic Patient Positioning in Computed Tomography Avatar Modeling of the Patient Surface Using a 3-Dimensional Camera

Natalia Saltybaeva et al.

INVESTIGATIVE RADIOLOGY (2018)

Review Physics, Nuclear

Statistical issues in searches for new phenomena in High Energy Physics

Louis Lyons et al.

JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS (2018)

Review Radiology, Nuclear Medicine & Medical Imaging

Current Applications and Future Impact of Machine Learning in Radiology

Garry Choy et al.

RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep Learning: A Primer for Radiologists

Gabriel Chartrand et al.

RADIOGRAPHICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Radiation Dose Reduction With Sinogram Affirmed Iterative Reconstruction Technique for Abdominal Computed Tomography

Mannudeep K. Kalra et al.

JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT

Sarabjeet Singh et al.

RADIOLOGY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

In-Plane Shielding for CT: Effect of Off-Centering, Automatic Exposure Control and Shield-to-Surface Distance

Mannudeep K. Kalra et al.

KOREAN JOURNAL OF RADIOLOGY (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Strategies for Reducing Radiation Dose in CT

Cynthia H. McCollough et al.

RADIOLOGIC CLINICS OF NORTH AMERICA (2009)

Review Medicine, General & Internal

Current concepts - Computed tomography - An increasing source of radiation exposure

David J. Brenner et al.

NEW ENGLAND JOURNAL OF MEDICINE (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

The influence of patient centering on CT dose and image noise

Thomas Toth et al.

MEDICAL PHYSICS (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of standard- and low-radiation-dose CT for quantification of emphysema

David S. Gierada et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

CT dose reduction and dose management tools: Overview of available options

Cynthia H. McCollough et al.

RADIOGRAPHICS (2006)

Review Radiology, Nuclear Medicine & Medical Imaging

Strategies for CT radiation dose optimization

MK Kalra et al.

RADIOLOGY (2004)