4.5 Article

Urinary tract infections in children: Testing a novel, noninvasive, point-of-care diagnostic marker

期刊

ACADEMIC EMERGENCY MEDICINE
卷 29, 期 3, 页码 326-333

出版社

WILEY
DOI: 10.1111/acem.14402

关键词

biomarkers; pediatric emergency medicine; urinary tract infections

资金

  1. Columbia University's CTSA [UL1TR001873]
  2. NCATS/NIH

向作者/读者索取更多资源

The study found that uNGAL levels from bagged and catheterized samples cannot be used interchangeably, and the sampling technique for bagged samples affects uNGAL levels.
Objectives Urinary neutrophil gelatinase-associated lipocalin (uNGAL) appears highly accurate to identify urinary tract infections (UTIs) when obtained via catheterization. Our primary aim was to determine the agreement in uNGAL levels between paired catheter and bag urine specimens. Our secondary aim was to compare the diagnostic test characteristics of quantitative uNGAL, dipstick uNGAL (a potential point-of-care test), and urinalysis (UA). Methods This was a prospective study of febrile children < 24 months evaluated for UTIs. We evaluated quantitative uNGAL at a previously identified threshold of 39.1 ng/mL, dipstick uNGAL at its built-in threshold of >50 ng/mL, and UA at standard thresholds for leukocyte esterase (LE). A positive urine culture was defined as >100,000 CFUs/mL of a pathogen. Results A total of 211 patients were included (10% with positive urine cultures); 116 had paired catheterized and bagged samples. The agreement between catheterized and bagged samples at a quantitative uNGAL cutoff of >= 39.1 ng/mL was 0.76 (95% confidence interval [CI] = 0.67 to 0.83) and 0.77 (95% CI = 0.68 to 0.84) at a uNGAL dipstick threshold of >50 ng/mL. The area under the receiver operating characteristic curve for uNGAL from a catheterized sample was 0.96 (95% CI = 0.89 to 1.00) compared to 0.93 (95% CI = 0.87 to -0.99) from a bagged sample. The sensitivities of catheterized sample quantitative and dipstick uNGAL (90.5%) were higher than UA at a LE threshold of >= 1+ (57.1%). Bagged-sample uNGAL had lower quantitative and dipstick specificities (both 73.8%) than from catheterized samples (94.3% and 95.3% respectively), similar to UA. Conclusions uNGAL from bagged and catheterized samples showed insufficient agreement to be used interchangeably. The low specificity of uNGAL from bagged samples suggests that sampling technique affects uNGAL levels.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据