3.8 Article

Aerosol generation during pulmonary function testing: Monitoring during different testing modalities

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/24745332.2021.1965926

关键词

Aerosol generation; oscillometry; pulmonary function laboratory; spirometry

资金

  1. Canadian Institute of Health Research (CIHR) Canadian Graduate Scholarship-Master's (CGS-M)

向作者/读者索取更多资源

A study quantified aerosol generation during different PFT modalities, showing higher aerosol counts compared to normal talking or coughing, but lower than PFT-induced coughing. Adherence to public health guidelines allows for safe reopening of PFT laboratories.
RATIONALE: : Severe acute respiratory syndrome caused by coronavirus 2 (SARS-CoV-2) was declared a pandemic on March 11, 2020. Countries entered lockdown, restricting medical activities to essential services. Pulmonary function tests (PFT) are crucial for management of lung diseases. With limited data regarding aerosol generation and the risk of disease transmission during PFTs, many laboratories closed. Our objective is to quantify aerosol generation during different PFT modalities. METHODS: We measured aerosol particles in the 0.3-10.0 mu m range with an Optical Particle Sizer (Model 3330; TSI Incorporated) and collected bioaerosols to detect respiratory pathogens during clinically indicated PFTs at a hospital-based laboratory during 2 time points in 2020. RESULTS: We monitored 81 and 41 individual multi-modality PFT sessions in June/July and December, respectively. Slow vital capacity, forced vital capacity and diffusion capacity generated higher aerosol counts compared to pre- and post-test room levels although all modalities were lower than during talking or coughing. The aerosol sizes generated were primarily 2.5-10 mu m. Oscillometry generated higher overall concentrations than room sampling, also primarily in the 2.5-10 mu m aerosols. The bioaerosol filters revealed no respiratory viruses or bacteria. CONCLUSIONS: While PFT can generate aerosols, it is less than normal speech with the exception of PFT-induced coughing. Our findings suggest the risk of SARS-CoV-2 transmission is not increased and support the re-opening of PFT laboratories that adhere to universal masking, use of personal protective equipment and stringent infection control protocols. We strongly endorse adherence to public health guidelines in the operation of PFT laboratories.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据