4.7 Article

Case study on the optimal thickness of phase change material incorporated composite roof under hot climate conditions

期刊

出版社

ELSEVIER
DOI: 10.1016/j.cscm.2021.e00522

关键词

PCM; Roof; Building energy; Decrement factor; Thermal performance; Time lag

资金

  1. Stipendium Hungaricum Programme
  2. Mechanical Engineering Doctoral School, Szent Istvan University, Godollo, Hungary

向作者/读者索取更多资源

This study experimentally investigated the optimal thickness of a phase change material (PCM) layer in composite roofs under severe exterior temperatures. The results showed that a 20 mm PCM thickness provided the best thermal performance, significantly reducing room temperature compared to the reference roof.
The current study experimentally investigates the optimal thickness of a phase change material (PCM) layer incorporated composite roof under severe exterior temperatures. Three PCM thicknesses, namely 10, 15 and 20 mm, are embedded inside a popular roof combination for residential buildings in Iraq compared with the reference roof without PCM. The composite roof is composed of Isogam (4 mm) as a roofing material, concrete (50 mm) as a main roof layer, and gypsum board (8 mm) as a cladding layer, which is the worst thermal-performed roof combination in the country. Each PCM thickness case's thermal performance has been evaluated considering energetic indicators based on room temperature, interior surface temperature, and average outside surface temperature. These indicators are room maximum temperature reduction (RMTR), average temperature fluctuation reduction (ATFR), decrement factor (DF) and time lag (TL). The experimental results showed that the room temperature could be reduced by up to 9 degrees C compared with the reference roof. Moreover, the best thermal performance is reported for the composite roof based 20 mm thickness which resulted in a maximum of 13.9 % 10.74 degrees C, 44.7 % and 190 min of respectively RMTR, ATFR, DF and TL more than that of the reference case. The study concluded that the thicker PCM layer results in better thermal performance. However, increasing PCM thickness from 10 to 15 mm and then to 20 mm reduced RMTR by 2.3 % and 0.4 %, respectively. Therefore, the effect of PCM heat discharging medium and the economic concern should be considered when installing large PCM thickness/quantity into real scale buildings. (C) 2021 The Author(s). Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据