4.4 Article

In vivo Analysis of the Resistance of the Meshes to Escherichia coli Infection

期刊

FRONTIERS IN SURGERY
卷 8, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fsurg.2021.644227

关键词

resistance; Escherichia coli; infection; synthetic mesh; biologic mesh; hernia

类别

资金

  1. National Natural Science Foundation of China [81600406]
  2. Three-year Talent Program of Changzheng Hospital

向作者/读者索取更多资源

The study found that compared to polytetrafluoroethylene mesh and polypropylene mesh, biologic mesh showed better resistance against E. coli within the concentration range of 10(6) to 10(8) CFU/ml. Prophylactic antibiotic treatment did not decrease the colonization rate of E. coli at 10(6) CFU/ml or 10(8) CFU/ml concentrations.
Background: The mesh infection is mostly related to the gram-negative bacteria, such as Escherichia coli (E. coli) for emergency surgery of incarcerated hernia. However, few study investigated the effects of E. coli concentration, mesh materials and antibiotic prophylaxis on mesh infection after hernioplasty. The aim of this study was to evaluate the bacterial resistance to E. coli for three different materials of mesh, and to measure the minimum E. coli concentration for mesh infection with and without antibiotic prophylaxis in a rat model. Methods: Three types of mesh (polytetrafluoroethylene, polypropylene, and biologic meshes) were used in the repair of an acute ventral hernia rat model in the setting of different concentrations of E. coli loads and antibiotics. At the 8th day after surgery, mesh samples were sent for microbiologic and histologic analyses. Results: The positive rates of bacterial culture increased with E. coli concentration. The biologic mesh showed better bacterial resistance compared to polytetrafluoroethylene mesh and polypropylene mesh when the concentration of E. coli ranges from 10(6) CFU/ml to 10(8) CFU/ml (P = 0.002 and P = 0.029, respectively). Prophylactical ceftriaxone treatment could not decrease the colonization rate of E. coli at 10(6) CFU/ml or 10(8) CFU/ml in each group (P > 0.05). The scores of neovascularization in polypropylene mesh and biologic mesh were similar, which was higher than that of polytetrafluoroethylene mesh (P < 0.05). Compared with other meshes, biologic mesh showed better tolerance to 10(6) CFU/ml E. coli with respect to inflammation, depth of inflammation, neovascularization, cellular repopulation and foreign body giant cells. Conclusion: The biologic mesh had better E. coli resistance compared to polytetrafluoroethylene mesh and polypropylene mesh when the E. coli concentration is higher than 10(6) CFU/ml in rats. Antibiotic prophylaxis was useful when the contamination was not particularly severe.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据