4.7 Article

Design of Bio-Absorbent Systems for the Removal of Hydrocarbons from Industrial Wastewater: Pilot-Plant Scale

期刊

TOXICS
卷 9, 期 7, 页码 -

出版社

MDPI
DOI: 10.3390/toxics9070162

关键词

hydrocarbons; bioremediation; industrial wastewater; pilot scale; microbial diversity; biofilm

资金

  1. Compania Logistica de Hidrocarburos S.A.

向作者/读者索取更多资源

This study focuses on the development and design of a treatment system at a pilot-plant scale for the remediation of hydrocarbons in industrial wastewater. By combining absorption and biodegradation methods, the system can effectively treat wastewater with high and low pollutant loads. Testing different flow rates and aeration conditions revealed optimal operation methods for different pollutant loads.
The objective of this study was the development and design of a treatment system at a pilot-plant scale for the remediation of hydrocarbons in industrial wastewater. The treatment consists of a combined approach of absorption and biodegradation to obtain treated water with sufficient quality to be reused in fire defense systems (FDSs). The plant consists of four vertical flow columns (bioreactors) made of stainless steel (ATEX Standard) with dimensions of 1.65 x 0.5 m and water volumes of 192.4 L. Each bioreactor includes a holder to contain the absorbent material (Pad Sentec polypropylene). The effectiveness of the treatment system has been studied in wastewater with high and low pollutant loads (concentrations higher than 60,000 mg L-1 of total petroleum hydrocarbons (TPH) and lower than 500 mg L-1 of TPHs, respectively). The pilot-plant design can function at two different flow rates, Q1 (180 L h(-1)) and Q2 (780 L h(-1)), with or without additional aeration. The results obtained for strongly polluted wastewaters showed that, at low flow rates, additional aeration enhanced hydrocarbon removal, while aeration was unnecessary at high flow rates. For wastewater with a low pollutant load, we selected a flow rate of 780 L h(-1) without aeration. Different recirculation times were also tested along with the application of a post-treatment lasting 7 days inside the bioreactor without recirculation. The microbial diversity studies showed similar populations of bacteria and fungi in the inlet and outlet wastewater. Likewise, high similarity indices were observed between the adhered and suspended biomass within the bioreactors. The results showed that the setup and optimization of the reactor represent a step forward in the application of bioremediation processes at an industrial/large scale.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据