Experimental study on heat transfer characteristics of closed thermosyphon at different volumes and inclination angles for variable vacuum pressures

期刊

出版社

ELSEVIER
DOI: 10.1016/j.csite.2021.101117

关键词

Vacuumed pipe; Experimental analysis; Thermal performance; Variable saturation temperatures; Two-phase flow; Inclination angles

资金

  1. Kutahya Dumlupinar University Scientific Research Projects Unit (DPU-BAP) [2017-55]
  2. National Scholarship Program for Ph.D. students (TUBITAK-BIDEB)
  3. Technological Research Council of Turkey

向作者/读者索取更多资源

This study experimentally investigated the thermal performance of vacuumed copper pipe with different volume values and inclination angles under variable vacuum pressures. The experimental boiling heat transfer coefficients showed good agreement with existing correlations in the literature, and the best thermal resistance was achieved in the vacuumed copper pipe filled with 10 ml of water at a 90-degree inclination angle.
In this study, the thermal performance of vacuumed copper pipe has been experimentally investigated by using different volume values of 5 ml, 10 ml, 15 ml, and 20 ml with inclination angles of 45 degrees, 60 degrees, and 90 degrees for variable vacuum pressures. For this purpose, the inner, outer diameter, and length of the vacuumed pipes filled with the distilled water were 26 mm, 28 mm, and 1500 mm, respectively. This copper pipe was vacuumed until the absolute pressure of 6.32 kPa and immersed in a heat source at a constant temperature of 82 degrees C at the beginning of the experiments. The surface temperatures of the vacuumed pipes were measured at twenty different points by using K-type thermocouples in two different data loggers. All calculations were performed as variable saturation temperatures at variable vacuum pressures with changing the time. According to the results, the experimental boiling heat transfer coefficients showed a good agreement with the correlations in the literature. Also, the best thermal resistance was obtained in the vacuumed copper pipe with a water volume of 10 ml at the inclination angle of 90. until the end of the experiment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据