Natural ventilation of residential building Atrium under fire scenario

期刊

出版社

ELSEVIER
DOI: 10.1016/j.csite.2021.101041

关键词

Natural ventilation; CFD; FDS; Smoke management; Fire simulat

资金

  1. German Jordanian University(GJU) , Jordan

向作者/读者索取更多资源

The study assessed the performance of a residential block with an Atrium using CFD simulations for natural ventilation and fire scenarios. Results showed the importance of ambient conditions for natural ventilation and recommended using operable louvres based on outdoor temperature. Location of fire within the Atrium was found to significantly impact air quality and ventilation strategy.
A residential block consists of two buildings connected via an Atrium is common nowadays because they could provide attractive, environment controlled and naturally lit spaces. The purpose of the current study is to undertake a performance based assessment of the proposed ventilation strategy and justify the performance through the use of computation fluid dynamics (CFD) approach. The three dimensional study utilized two available CFD packages: CFD ACE + for natural ventilation simulations and Fire Dynamic Simulator (FDS) for fire simulations. Four different louver opening areas were examined to see their effect on air speed and temperature of air within the Atrium. Another five scenarios were examined with the existence of fire within the Atrium. Results showed that the natural ventilation solution is dependent on ambient conditions outside the Atrium. Therefore, operable louvres are recommended to be fully closed under extreme weathers and to have it fully opened at an outdoor temperature of 19 degrees C-27 degrees C. In the case of a fire being ignited within the Atrium, it is found that the location of the fire has a significant impact on the air quality within the Atrium. It is found that when the fire is located in the open void area to the east of the Atrium, a simple ventilating strategy is capable of providing the required ventilating capacity to maintain the Atrium safe for evacuating the occupants. When the fire is located at the lifts and stairs area, however, the ventilation strategy requires a more sensitive approach. It is found that the natural ventilation approach failed in extracting the smoke out of the Atrium (Lifts lobby) unlike when the fire was located in the void area. However, the air temperature within the Atrium is found to meet the design requirements of lower than 60 degrees C.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据