Efficacy of Loop-Mediated Isothermal Amplification for H. pylori Detection as Point-of-Care Testing by Noninvasive Sampling

期刊

DIAGNOSTICS
卷 11, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/diagnostics11091538

关键词

Helicobacter pylori; gastric cancer; noninvasive sampling; LAMP; POCT

资金

  1. European Research Council [682663]
  2. European Research Council (ERC) [682663] Funding Source: European Research Council (ERC)

向作者/读者索取更多资源

The study evaluated the LAMP assay for H. pylori detection using noninvasive and self-sampling methods, showing high specificity and sensitivity for potential clinical applications. The combination of LAMP assay with noninvasive sampling methods has the potential to be a useful point-of-care testing approach for detecting H. pylori infection in clinic settings and screening programs.
For targeted eradication of Helicobacter pylori (H. pylori) to reduce gastric cancer burden, a convenient approach is definitely needed. The purpose of this study was to evaluate the LAMP assay for H. pylori detection using samples collected by noninvasive and self-sampling methods. The available LAMP assay for H. pylori detection was appraised and verified using reference and clinically isolated H. pylori strains. In addition, a clinical study was conducted to assess the LAMP assay on 51 patients, from whom saliva, oral brushing samples, feces, corpus, and antrum specimens were available. Clarithromycin resistance was also analysed through detection of A2143G mutation using the LAMP-RFLP method. The validation and verification analysis demonstrated that the LAMP assay had an acceptable result in terms of specificity, sensitivity, reproducibility, and accuracy for clinical settings. The LAMP assay showed a detection limit for H. pylori down to 0.25 fg/mu L of genomic DNA. An acceptable consensus was observed using saliva samples (sensitivity 58.1%, specificity 84.2%, PPV 85.7%, NPV 55.2%, accuracy 68%) in comparison to biopsy sampling as the gold standard. The performance testing of different combinations of noninvasive sampling methods demonstrated that a combination of saliva and oral brushing could achieve a sensitivity of 74.2% and a specificity of 57.9%. A2143G mutation detection by LAMP-RFLP showed perfect consensus with Sanger sequencing results. It appears that the LAMP assay in combination with noninvasive and self-sampling as a point-of-care testing (POCT) approach has potential usefulness to detect H. pylori infection in clinic settings and screening programs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据