4.7 Article

A rapid and sensitive colorimetric method for the detection of cyanide ions in aqueous samples

期刊

出版社

ELSEVIER
DOI: 10.1016/j.eti.2021.101973

关键词

Potassium cyanide; Cyanide detection; Cyanocobalamin; Fluorometry; Chromogenic test-strips

资金

  1. Council of Scientific and Industrial Research, India (CSIR Mission-Mode Programme on Food and Consumer Safety Solutions, FOCUS) [HCP-0016]
  2. CSIR, India

向作者/读者索取更多资源

The study formulated a recognition solution for cyanide detection and developed chromogenic test-strips, with a detection limit of 0.27 ppm for the method and 1 ppm for the test-strips. The spectrophotometric method detected cyanide contamination of 0.77 ppm, 2.56 ppm and 2.71 ppm in samples from canal, tannery and textile industry effluents, respectively. The developed method and test-strips are selective for cyanide and unaffected by interferents like Cl-, Br-, I-, HCO-, PO3-, SO2- and AcO-.
Cyanide is a highly toxic environmental pollutant that bind to metalloenzymes such cytochrome C oxidase causing respiratory arrest and death in aquatic and terrestrial organisms. Here, a recognition solution for cyanide detection has been formulated that was further used for the development of chromogenic test-strips. The interaction of the recognition solution with potassium cyanide produces a colorimetric response quantifiable at 586 nm as well as a distinctive fluorescence spectrum with emission at 620 nm. Potassium cyanide was identified in aqueous samples using standard spectrophotometric method with a limit of detection of 0.27 +/- 0.1 ppm. The samples collected from canal, tannery and textile industry effluents tested with the spectrophotometric method showed cyanide contamination of 0.77 ppm, 2.56 ppm and 2.71 ppm, respectively. The chromogenic test-strip showed a limit of detection of 1 ppm with the standards aqueous and environmental samples. The developed method and test-strips are selective for cyanide and the response is unaffected by the presence of interferents such as Cl-, Br-, I-, HCO-, PO3-, SO2- and AcO- in the matrix. The developed chromogenic test-strips can be used in point-of-use applications where sophisticated equipments are not available. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据