4.6 Article

Retrospective Performance Analyses of over Two Million US QuantiFERON Blood Sample Results

期刊

MICROBIOLOGY SPECTRUM
卷 9, 期 1, 页码 -

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/Spectrum.00096-21

关键词

assay performance; indeterminate rates; Mycobacterium tuberculosis; positivity rates; QuantiFERON tests; QFT tests

向作者/读者索取更多资源

This study retrospectively analyzed performance data from over 2 million samples for both the QFT-GIT and QFT-Plus tests. Results showed a higher proportion of positive results with QFT-GIT, and a lower proportion of indeterminate results with the 1-tube method of QFT-Plus.
Both the QuantiFERON-TB Gold Plus (QFT-Plus) and the QuantiFERON-TB Gold In-Tube (QFT-GIT) tests are interferon gamma (IFN-gamma) release assays (IGRAs) intended to detect in vitro cell-mediated immune responses to Mycobacterium tuberculosis antigens. In this study, we retrospectively analyzed performance data for both the QFT-GIT and QFT-Plus test systems from over 2 million samples. QFT-Plus and QFT-GIT testing was performed as specified in the respective package inserts at 23 Quest Diagnostics sites. Blood specimens were collected from individuals in all 50 states from November 2018 through December 2019. Retrospective analyses compared the proportion of positive, indeterminate, and conversion/reversion results. The overall proportion of QFT-positive results was 7% for both the QFT-Plus and QFT-GIT. The proportion of positive results was highest for QFT-GIT (7.5%) followed by the heparin 1-tube QFT-Plus (7.2%); a lower proportion of positives was observed with the 4-tube (all four QFT tubes were used in blood collection) QFT-Plus (6.0%). The proportions of indeterminate results for the 1-tube (heparin-only tube collection) and 4-tube QFT-Plus methods were less than 1% and 4%, respectively. This study indicates a higher proportion of positive results for M. tuberculosis than data from other studies. Additionally, the proportion of indeterminate QFT results were markedly lower when the sample was transported in one lithium-heparin tube instead of direct inoculation into 4 QFT-Plus tubes at the site of blood collection. IMPORTANCE In this study, we retrospectively analyzed results from both the QFT-GIT and QFT-Plus test systems from over 2 million blood specimens. The variables analyzed were (i) QFT positivity rates among various U.S. populations, (ii) indeterminate rates among various types of blood draws and how often an indeterminate result was resolved within 30 days after the initial draw, and (iii) the association of TB1 and TB2 antigen tubes with IGRA reversion and conversion events from serial QFT testing. This is, to our knowledge, the largest QFT study representing patients from an extensive geographic coverage across the United States and U.S. territories.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据