4.6 Article

Anti-Spike Protein Assays to Determine SARS-CoV-2 Antibody Levels: a Head-to-Head Comparison of Five Quantitative Assays

期刊

MICROBIOLOGY SPECTRUM
卷 9, 期 1, 页码 -

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/Spectrum.00247-21

关键词

comparison; quantitative antibody assays; SARS-CoV-2; vaccination; assay standardization; immunization; quantitative methods; serology

资金

  1. DiaSorin

向作者/读者索取更多资源

Reliable quantification of the antibody response to SARS-CoV-2 is crucial for identifying possible vaccine failure and estimating protection time. Despite good overall agreement, the performance of five antibody quantification assays showed differences that highlight the need for further standardization of SARS-CoV-2 serology.
Reliable quantification of the antibody response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is highly relevant, e.g., for identifying possible vaccine failure and estimating the time of protection. Therefore, we evaluated five different anti-SARS-CoV-2 antibody assays regarding the quantification of antispike (S) antibodies. Sera from 69 SARS-CoV-2-naive individuals 21 6 1 days after vaccination with a single dose of BNT162b2 (Pfizer/BioNTech) were tested using the following quantitative assays: Roche S total antibody, DiaSorin trimeric spike IgG, DiaSorin S1/S2 IgG, Abbott II IgG, and Serion/Virion IgG. Results were further compared to the percent inhibition calculated from a surrogate virus neutralization test (sVNT). Individual values were distributed over several orders of magnitude for all assays. Although the assays were in good overall agreement (rho = 0.80 to 0.94), PassingBablok regression revealed systematic constant and proportional differences, which could not be eliminated by converting the results to binding antibody units (BAU) per milliliter, as suggested by the manufacturers. Seven (10%) individuals had negative sVNT results (i.e., <30% inhibition). These samples were identified by most assays and yielded significantly lower binding antibody levels. Although all assays showed good correlation, they were not interchangeable, even when converted to BAU per milliliter using the WHO international standard for SARS-CoV-2 immunoglobulin. This highlights the need for further standardization of SARS-CoV-2 serology. IMPORTANCE Reliable quantification of the antibody response to SARS-CoV-2 is highly relevant, e.g., for identifying possible vaccine failure and estimating the time of protection. We compared the performance of five CE marked tests that quantify antibodies against the viral spike protein. Our findings suggest that, although all assays showed good correlation, their results were not interchangeable, even when converted to BAU per milliliter using the WHO international standard for SARS-CoV-2 immunoglobulin. This highlights the need for further standardization of SARS-CoV-2 serology.

作者