4.1 Article

Fluorescence-guided resection of experimental malignant glioma using cetuximab-IRDye 800CW

期刊

BRITISH JOURNAL OF NEUROSURGERY
卷 29, 期 6, 页码 850-858

出版社

TAYLOR & FRANCIS LTD
DOI: 10.3109/02688697.2015.1056090

关键词

fluorescence-guided surgery; antibody imaging; cetuximab; IRDye 800CW

资金

  1. UAB Brain Tumour Core Facility [USPHS NCI P20CA151129]
  2. UAB Comprehensive Cancer Center small animal core facility [P30 CA013148]
  3. NIH [5T32CA091078-12, R21CA179171]

向作者/读者索取更多资源

The standard treatment for glioblastoma multiforme (GBM) remains maximal safe surgical resection. Here, we evaluated the ability of a systemically administered antibody-dye probe conjugate (cetuximab-IRDye 800CW) to provide sufficient fluorescent contrast for surgical resection of disease in both subcutaneous and orthotopic animal models of GBM. Multiple luciferase-positive GBM cell lines (D-54MG, U-87MG, and U-251MG; n = 5) were implanted in mouse flank and tumors were fluorescently imaged daily using a closed-field near-infrared (NIR) system after cetuximab-IRDye 800CW systemic administration. Orthotopic models were also generated (n = 5), and tumor resection was performed under white light and fluorescence guidance using an FDA-approved wide-field NIR imaging system. Residual tumor was monitored using luciferase imaging. Immunohistochemistry was performed to characterize tumor fluorescence, epidermal growth factor receptor (EGFR) expression, and vessel density. Daily imaging of tumors revealed an average tumor-to-background (TBR) of 4.5 for U-87MG, 4.1 for D-54MG, and 3.7 for U-251MG. Fluorescence intensity within the tumors peaked on day-1 after cetuximab-IRDye 800CW administration, however the TBR increased over time in two of the three cell lines. For the orthotopic model, TBR on surgery day ranged from 19 to 23 during wide-field, intraoperative imaging. Surgical resection under white light on day 3 after cetuximab-IRDye 800CW resulted in an average 41% reduction in luciferase signal while fluorescence-guided resection using wide-field NIR imaging resulted in a significantly (P = 0.001) greater reduction in luciferase signal (87%). Reduction of luciferase signal was found to correlate (R-0002> 2 = 0.99) with reduction in fluorescence intensity. Fluorescence intensity was found to correlate (P < 0.05) with EGFR expression in D-54MG and U-251MG tumor types but not U-87MG. However, tumor fluorescence was found to correlate with vessel density for the U-87MG tumors. Here we show systemic administration of cetuximab-IRDye 800CW in combination with wide-field NIR imaging provided robust and specific fluorescence contrast for successful localization of disease in subcutaneous and orthotopic animal models of GBM.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据