4.5 Article

Continuous diffusion spectrum computation for diffusion-weighted magnetic resonance imaging of the kidney tubule system

期刊

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY
卷 11, 期 7, 页码 3098-3119

出版社

AME PUBL CO
DOI: 10.21037/qims-20-1360

关键词

Kidney; tubular volume fraction; MRI; diffusion-weighted imaging; non-negative least squares (NNLS)

资金

  1. German Research Foundation [Gefoerdert durch die Deutsche Forschungsgemeinschaft (DFG)] [394046635, SFB 1365]
  2. Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) [394046635, SFB 1365]

向作者/读者索取更多资源

The study demonstrates the feasibility of using non-negative least squares modeling for diffusion-weighted MRI of the kidney tubule system, showing potential for examining diffusion compartments associated with renal pathophysiology, such as ITV fraction and different degrees of fibrosis.
Background: The use of rigid multi-exponential models (with a priori predefined numbers of components) is common practice for diffusion-weighted MRI (DWI) analysis of the kidney. This approach may not accurately reflect renal microstructure, as the data are forced to conform to the a priori assumptions of simplified models. This work examines the feasibility of less constrained, data-driven non-negative least squares (NNLS) continuum modelling for DWI of the kidney tubule system in simulations that include emulations of pathophysiological conditions. Methods: Non-linear least squares (LS) fitting was used as reference for the simulations. For performance assessment, a threshold of 5% or 10% for the mean absolute percentage error (MAPE) of NNLS and LS results was used. As ground truth, a tri-exponential model using defined volume fractions and diffusion coefficients for each renal compartment (tubule system: D-tubules, f(tubules); renal tissue: D-tissue, f(tissue); renal blood: D-blood, f(blood);) was applied. The impact of: (I) signal-to-noise ratio (SNR) =40-1,000, (II) number of b-values (n=10-50), (III) diffusion weighting (b-range(small) =0-800 up to b-range(large) = 0-2,180 s/mm(2)), and (IV) fixation of the diffusion coefficients D-tissue and D-blood was examined. NNLS was evaluated for baseline and pathophysiological conditions, namely increased tubular volume fraction (ITV) and renal fibrosis (10%: grade I, mild) and 30% (grade II, moderate). Results: NNLS showed the same high degree of reliability as the non-linear LS. MAPE of the tubular volume fraction (f(tubules)) decreased with increasing SNR. Increasing the number of b-values was beneficial for f(tubules) precision. Using the b-rangelarge led to a decrease in MAPEf(tubules) compared to b-range(small). The use of a medium b-value range of b=0-1,380 s/mm(2) improved f(tubules) precision, and further b(max) increases beyond this range yielded diminishing improvements. Fixing D-blood and D-tissue significantly reduced MAPEf(tubules) and provided near perfect distinction between baseline and ITV conditions. Without constraining the number of renal compartments in advance, NNLS was able to detect the (fourth) fibrotic compartment, to differentiate it from the other three diffusion components, and to distinguish between 10% vs. 30% fibrosis. Conclusions: This work demonstrates the feasibility of NNLS modelling for DWI of the kidney tubule system and shows its potential for examining diffusion compartments associated with renal pathophysiology including ITV fraction and different degrees of fibrosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据