4.5 Article

Feasibility of dual-phase 99mTc-MDP SPECT/CT imaging in rheumatoid arthritis evaluation

期刊

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY
卷 11, 期 6, 页码 2333-2343

出版社

AME PUBL CO
DOI: 10.21037/qims-20-996

关键词

Bone scan; rheumatoid arthritis; SPECT/CT; soft tissue vascularity; osteoblastic response

资金

  1. Philips Healthcare
  2. National Institutes of Health [R01 AR076088]

向作者/读者索取更多资源

This study demonstrates the feasibility of dual-phase SPECT/CT scanning in assessing small joints of RA patients, with reliable quantitative and qualitative measures obtained from the images. The findings suggest that SPECT/CT may offer a unique approach for evaluating synovitis and osseous involvement in RA joints.
Background: To prospectively demonstrate the feasibility of performing dual-phase SPECT/CT for the assessment of the small joints of the hands of rheumatoid arthritis (RA) patients, and to evaluate the reliability of the quantitative and qualitative measures derived from the resulting images. Methods: A SPECT/CT imaging protocol was developed in this pilot study to scan both hands simultaneously in participants with RA, in two phases of 99mTc-MDP radiotracer uptake, namely the softtissue blood pool phase (within 15 minutes after radiotracer injection) and osseous phase (after 3 hours). Joints were evaluated qualitatively (normal vs. abnormal uptake) and quantitatively [by measuring a newly developed metric, maximum corrected count ratio (MCCR)]. Qualitative and quantitative evaluations were repeated to assess reliability. Results: Four participants completed seven studies (all four were imaged at baseline, and three of them at follow-up after 1-month of arthritis therapy). A total of 280 joints (20 per hand) were evaluated. The MCCR from soft-tissue phase scans was significantly higher for clinically abnormal joints compared to clinically normal ones; P<0.001, however the MCCR from the osseous phase scans were not different between the two joint groups. Intraclass Correlation Coefficient (ICC) for MCCR was excellent [0.9789, 95% confidence interval (CI): 0.9734-0.9833]. Intra-observer agreement for qualitative SPECT findings was substantial for both the soft-tissue phase (kappa =0.78, 95% CI: 0.72?0.83) and osseous-phase (kappa =0.70, 95% CI: 0.64-0.76) scans. Conclusions: Extracting reliable quantitative and qualitative measures from dual-phase 99mTc-MDP SPECT/CT hand scans is feasible in RA patients. SPECT/CT may provide a unique means for assessing both synovitis and osseous involvement in RA joints using the same radiotracer injection.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据