4.7 Article

Design and fabrication of a vigorous cavitation-on-a-chip device with a multiple microchannel configuration

期刊

MICROSYSTEMS & NANOENGINEERING
卷 7, 期 1, 页码 -

出版社

SPRINGERNATURE
DOI: 10.1038/s41378-021-00270-1

关键词

-

资金

  1. TUBITAK (The Scientific and Technological Research Council of Turkey) [217M869]
  2. KTH Royal Institute of Technology
  3. Sabanci University Nanotechnology Research and Applications Center (SUNUM)
  4. KTH Energy Platform

向作者/读者索取更多资源

A new 'cavitation-on-a-chip' device is proposed in this study to reduce the upstream pressure required for hydrodynamic cavitation, with further pressure reduction achieved by using poly(vinyl alcohol) microbubble suspension. Different cavitating flow patterns with various intensities can be observed within the same device, and cavitating flows intensify faster in the proposed device compared to previous studies. This next-generation device has high potential for applications in microfluidic/organ-on-a-chip devices, such as integrated drug release and tissue engineering.
Hydrodynamic cavitation is one of the major phase change phenomena and occurs with a sudden decrease in the local static pressure within a fluid. With the emergence of microelectromechanical systems (MEMS), high-speed microfluidic devices have attracted considerable attention and been implemented in many fields, including cavitation applications. In this study, a new generation of 'cavitation-on-a-chip' devices with eight parallel structured microchannels is proposed. This new device is designed with the motivation of decreasing the upstream pressure (input energy) required for facile hydrodynamic cavitation inception. Water and a poly(vinyl alcohol) (PVA) microbubble (MB) suspension are used as the working fluids. The results show that the cavitation inception upstream pressure can be reduced with the proposed device in comparison with previous studies with a single flow restrictive element. Furthermore, using PVA MBs further results in a reduction in the upstream pressure required for cavitation inception. In this new device, different cavitating flow patterns with various intensities can be observed at a constant cavitation number and fixed upstream pressure within the same device. Moreover, cavitating flows intensify faster in the proposed device for both water and the water-PVA MB suspension in comparison to previous studies. Due to these features, this next-generation 'cavitation-on-a-chip' device has a high potential for implementation in applications involving microfluidic/organ-on-a-chip devices, such as integrated drug release and tissue engineering.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据