4.7 Review

Evaluation methods for mechanical biocompatibility of hernia repair meshes: respective characteristics, application scope and future perspectives

期刊

出版社

ELSEVIER
DOI: 10.1016/j.jmrt.2021.05.086

关键词

Mechanical biocompatibility; Mechanical characterization; Hernia repair mesh; Soft tissue repair; Numerical modeling

资金

  1. National Key R&D Program of China [2017YFC1104703]
  2. National Natural Science Foundation of China [31771042]
  3. Fok Ying Tung Education Foundation [141039]
  4. Fund of Key Laboratory of Advanced Materials of Ministry of Education
  5. State Key Laboratory of Powder Metallurgy (Central South University)
  6. International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Ministry of Science and Technology of China
  7. 111 Project [B13003]

向作者/读者索取更多资源

Soft tissue substitutes undergo large deformations in vivo, and it is important to match the deformation behavior between substitute and tissue for effective repair. Evaluation methods for mechanical biocompatibility include physicomechanical testing, non-invasive measurement, and numerical modeling, each with its own advantages and limitations. A comprehensive summary of these methods is needed to guide the selection and improvement of evaluation methods for soft tissue substitutes.
Soft tissue substitutes are subjected to large deformation in vivo, so the matching of deformation behavior between substitute and tissue is a complex but important criterion for soft tissue repair. Hernia repair mesh is a typical soft tissue substitute, and the mismatch of mechanical properties between mesh and tissues normally leads to decline in the quality of life and hernia recurrence. Therefore, before clinical applications, the evaluation for the mechanical biocompatibility of mesh is particularly important. Currently, several methods have been developed to evaluate mechanical biocompatibility of soft tissue substitutes, including physicomechanical testing, non-invasive measurement, and numerical modeling, etc. However, a comprehensive summary is lacking to provide reference for the selection, implementation and optimization of these methods. In this paper, taking the hernia repair mesh as an example, we systematically review these methods from following aspects: (1) proposing critical issues that need to be paid attention to when performing physicomechanical testing on substitutes, (2) systematically analyzing characteristics and applicable sample types for several typical physicomechanical testing techniques, (3) comprehensively summarizing the advantages and limitations of the main non-invasive measurement methods, and showing the potentials of these methods, (4) emphasizing and dissecting the merits of numerical modeling compared with physicomechanical testing and non-invasive measurement, and proposing the existing and potential improvements of this method. Furthermore, the application scope and future development direction of these methods are proposed. This paper might play an important role in guiding the selection and improvement of evaluation methods for mechanical biocompatibility of soft tissue substitutes. (c) 2021 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据