4.7 Article

The assessment of usage of epoxy based micro and nano-structured composites enriched with Bi2O3 and WO3 particles for radiation shielding

期刊

RESULTS IN PHYSICS
卷 26, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.rinp.2021.104423

关键词

Epoxy; Radiation shielding; Composites; MCNP6 simulation; Gamma spectroscopy

资金

  1. Yildiz Technical University Scientific Research Projects Coordination Department [FDK-2019-3182]
  2. Scientific and Technological Research Council of Turkey (TUBITAK) [2228-B]

向作者/读者索取更多资源

The study investigated the radiation shielding performance of epoxy-based composites reinforced with micro and nano Bi2O3 and WO3, showing that nano particles are more effective in attenuating incoming photons than micro particles. Experimental and simulation results demonstrated that composites with higher Bi2O3 and WO3 contents have potential in shielding harmful effects of diagnostic radionuclides utilized in nuclear medicine and imaging devices.
This study has been devoted to investigate the radiation shielding performance of epoxy-based micro and nano Bi2O3 and WO3 reinforced composites. While the research has been carried out by using experimental data and MCNP6 simulation for the micro-structured composites; the effect of nano Bi2O3 and WO3 particles addition on the radiation shielding property of epoxy has been discussed by using experimental data. While the gamma-ray spectroscopy experiments have been carried by using NaI(Tl) scintillation detector and Ba-133, Cs-137, and Co-60 sources, the MCNP version 6.2 code has been utilized for the simulation. The experimental and MCNP6 simulation results showed good consistency for both particle reinforcement and different incoming photon energies. Particle size effect investigation also indicated that for both kinds of dopant particles, the nano dopant is more successful in attenuating the intensity of incoming photons than the micro dopant even if they are used in the same percentages. In conclusion, it can be suggested that the micro and nano-structured composites having the highest Bi2O3 and WO3 contents have a considerable potential to shield the harmful effects of some of the diagnostic radionuclides utilized in nuclear medicine as well as the radiation imaging machines such as roentgen, mammography or PET scans.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据