4.6 Article

Alteration of Vestibular Function in Pediatric Cochlear Implant Recipients

期刊

FRONTIERS IN NEUROLOGY
卷 12, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fneur.2021.661302

关键词

cochlear implantation; vestibular dysfunction; caloric test; damped rotation test; perimodiolar electrode

资金

  1. Health and Labor Sciences Research Grant for Research on Rare and Intractable Diseases from the Ministry of Health, Labour and Welfare of Japan [20FC1048]
  2. JSPS KAKENHI [JP19K18787]

向作者/读者索取更多资源

Vestibular dysfunction is a complication of cochlear implantation in pediatric patients, with cVEMP being the most affected test post-implantation. Minimally invasive surgery using a round window approach or an extended round window approach with straight electrodes is recommended for preserving vestibular function after CI in children.
Background: Vestibular dysfunction is a complication of cochlear implantation (CI). Reports on the evaluation of vestibular function before and after CI are limited, especially in children. We investigated the effect of CI on vestibular function in pediatric patients. Patients and Methods: We routinely evaluated vestibular function before but not immediately after CI. Therefore, patients who underwent sequential bilateral CI were enrolled in this study. Seventy-three children who underwent sequential CI from 2003 to 2020 at our hospital were included. Since the vestibular function of the first implanted ear was evaluated before the second surgery for the contralateral ear, post-CI evaluation timing differed among the cases. The evaluation included a caloric test, a cervical vestibular-evoked myogenic potential (cVEMP) test, and a damped rotation test. The objective variables included the results of these tests, and the explanatory variables included the age at surgery, cause of hearing loss, electrode type, and surgical approach used. The associations of these tests were analyzed. Results: cVEMP was the most affected after CI (36.1%), followed by the caloric test (23.6%), and damped rotation test (7.8%). Cochleostomy was significantly more harmful than a round window (RW) approach or an extended RW approach based on the results of the caloric test (p = 0.035) and damped rotation test (p = 0.029). Perimodiolar electrodes affected the caloric test results greater than straight electrodes (p = 0.041). There were no significant associations among these tests' results. Conclusions: Minimally invasive surgery in children using a round window approach or an extended round window approach with straight electrodes is desirable to preserve vestibular function after CI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据