4.6 Article

Novel Flexible PVDF-TrFE and PVDF-TrFE/ZnO Pressure Sensor: Fabrication, Characterization and Investigation

期刊

MICROMACHINES
卷 12, 期 6, 页码 -

出版社

MDPI
DOI: 10.3390/mi12060602

关键词

PVDF-TrFE; PVDF-TrFE/ZnO; beta phase crystal; human pulsation sensor

资金

  1. Hong Kong Polytechnic University

向作者/读者索取更多资源

In this paper, a novel flexible pressure sensor with high sensitivity was developed by improving the beta-phase crystallinity and piezoelectricity of the PVDF-TrFE membranes. The addition of ZnO nanofillers and the annealing process significantly increased the sensitivity of the prototype sensor, showing great potential for healthcare device applications.
With the development of human healthcare devices, smart sensors, e-skins, and pressure sensors with outstanding sensitivity, flexibility, durability and biocompatibility have attracted more and more attention. In this paper, to develop a novel flexible pressure sensor with high sensitivity, different poly (vinylidene fluoride-trifluoroethylene) (PVDF-TrFE)-based composite membranes were fabricated, characterized and tested. To improve the beta-phase crystallinity and piezoelectricity of the membranes, and for the purpose of comparison, nano ZnO particles with different concentrations (99:1, 9:1 in a weight ratio of PVDF-TrFE to ZnO) were, respectively added into PVDF-TrFE polymer acting as a nucleating agent and dielectric material. To facilitate the formation of beta-phase crystal, the membranes were fabricated by electrospinning method. After the electrospinning, an annealing process was conducted to the fabricated membranes to increase the size and content of beta-phase crystal. Then, the fabricated PVDF-TrFE membranes, acting as the core sensing layer, were, respectively built into multiple prototype sensors in a sandwich structure. The sensitivity of the prototype sensors was tested by an auto-clicker. The stimulation of the auto-clicker on the prototype sensors generated electrical signals, and the electrical signals were collected by a self-built testing platform powered by LabVIEW. As a result, combining the addition of ZnO nanofillers and the annealing process, a highly sensitive pressure sensor was fabricated. The optimal peak-to-peak voltage response generated from the prototype sensor was 1.788 V which shows a 75% increase compared to that of the pristine PVDF-TrFE sensor. Furthermore, a human pulse waveform was captured by a prototype sensor which exhibits tremendous prospects for application in healthcare devices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据