4.5 Article

Automated Collateral Flow Assessment in Patients with Acute Ischemic Stroke Using Computed Tomography with Artificial Intelligence Algorithms

期刊

WORLD NEUROSURGERY
卷 155, 期 -, 页码 E748-E760

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.wneu.2021.08.136

关键词

Artificial intelligence; Brain; Computed tomography perfusion; Ischemic stroke

向作者/读者索取更多资源

This study demonstrated the successful use of artificial intelligence algorithms in evaluating collateral circulation in AIS patients, providing an effective tool for determining reperfusion-eligible patients.
BACKGROUND: Collateral circulation is associated with improved functional outcome in patients with large vessel occlusion acute ischemic stroke (AIS) who undergo reperfusion therapy. Assessment of collateral flow can be time consuming, subjective, and difficult because of complex neurovasculature. This study assessed the ability of multiple artificial intelligence algorithms in determining collateral flow of patients with AIS. METHODS: Two hundred patients with AIS between March 2019 and January 2020 were included in this retrospective study. Peak arterial computed tomography perfusion volumes were used to assess collateral scores. Neural networks were developed for dichotomized (double dagger 50% or <50%) and multiclass (0% filling, 0%-50% filling, 50%100% filling, or 100% filling) collateral scoring. Maximum intensity projections from axial and anteroposterior (AP) views were synthesized for each bone subtracted threedimensional volume and used as network inputs separately and together, along with three-dimensional data. Training:testing:validation splits of 60:30:10 and 20 iterations of Monte Carlo cross-validation were used. Network performance was assessed using 95% confidence intervals of accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: The axial and AP input combination provided the most accurate results for dichotomized classification: accuracy, 0.85 +/- 0.01; sensitivity, 0.88 +/- 0.02; specificity, 0.82 +/- 0.03; PPV, 0.86 +/- 0.02; and NPV, 0.83 +/- 0.03. Similarly, the axial and AP input combination provided the best results for multiclass classification: accuracy, 0.80 +/- 0.01; sensitivity, 0.64 +/- 0.01; specificity, 0.85 +/- 0.01; PPV, 0.65 +/- 0.02; and NPV, 0.85 +/- 0.01. CONCLUSIONS: This study reports one of the first artificial intelligence-based algorithms capable of accurately and efficiently assessing collateral flow of patients with AIS. This automated method for determining collateral filling could streamline clinical workflow, reduce bias, and aid in clinical decision making for determining reperfusion-eligible patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据