4.5 Article

Enhancing shear capacity of thin slabs with CFRP shear reinforcement: Experimental study

期刊

STRUCTURAL CONCRETE
卷 22, 期 5, 页码 3057-3073

出版社

ERNST & SOHN
DOI: 10.1002/suco.202100325

关键词

CFRP; shear; shear slenderness; size effect; slabs; textile reinforcement

资金

  1. Federal Ministry of Education and Research [03ZZ0380]

向作者/读者索取更多资源

This study investigates the one-way shear capacity of slabs with and without carbon FPR shear reinforcement. The experimental results show that both planar and preformed C-shaped grids enhance the shear capacity of thin slabs.
Employing non-metallic reinforcement made of fiber-reinforced polymers (FRPs) as textile grids is one promising extension of the utilization range of FRP in concrete construction, and thin planar elements reinforced in this manner have high application potential in bridge or parking garage decks, in facades, or in webs and flanges of hollow core cross-sections. Existing models for predicting the shear resistance of such elements were derived for solid cross-sectional dimensions similar to conventional steel-reinforced structures, and their application to thin slabs is debatable. This paper presents the results of an extensive experimental program on the one-way shear capacity of slabs without and with carbon FPR textile shear reinforcement. A variation of member height, shear slenderness, and shear reinforcement ratio allowed for analysis of the most relevant influencing factors on shear resistance. Both planar and preformed C-shaped grids enhance the shear capacity and are suitable as shear reinforcement in thin slabs. The experimental results are the foundation for the extension of shear models to thin slabs with FRP reinforcement and for derivation of new unifying shear models that are applicable to a wider range of reinforcement materials and member dimensions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据