Preclinical study to improve microbubble-mediated drug delivery in cancer using an ultrasonic probe with an interchangeable acoustic lens

期刊

SCIENTIFIC REPORTS
卷 11, 期 1, 页码 -

出版社

NATURE RESEARCH
DOI: 10.1038/s41598-021-92097-z

关键词

-

资金

  1. National Research Foundation of Korea (NRF) - Korea government (MSIT) [2020R1C1C1008716]
  2. Brain Research Program through the NRF - MSIT [2016M3C7A1913845]
  3. KIST Institutional Program [2E30964]
  4. National Research Foundation of Korea [2020R1C1C1008716] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

It has been demonstrated that unfocused ultrasound with microbubbles and an interchangeable acoustic lens can enhance drug delivery efficiency by overcoming the limitations of a narrow pressure field. A concave lens suitable for an ultrasound-phased array probe was designed to optimize microbubble destruction, leading to successful drug delivery enhancement in in vitro and animal experiments. This system shows promise in providing sufficient ultrasound irradiation to microbubbles for improved drug delivery effectiveness.
Focused ultrasound with microbubbles (FUS-MBs) has shown that it can lead to an efficient drug delivery system (DDS) involving the oscillation and destruction of the MB but is limited in drug delivery due to its narrow pressure field. However, unfocused ultrasound with MBs (UUS-MBs) and an interchangeable acoustic lens can tune and enhance the pressure field for MB destruction to overcome the disadvantages of FUS-MB DDSs. We designed a lens suitable for an ultrasound-phased array probe and studied the optimal treatment conditions for MB destruction in vitro through an optical imaging setup. The DDS effects were evaluated in a rat hepatoma model using doxorubicin (DOX) treatment. A concave lens with a radius of curvature of 2.6 mm and a thickness of 4 mm was selected and fabricated. UUS-MBs with the acoustic lens at 60 V-pp for 32 cycles and a PRF of 1 kHz could induce MB destruction, promoting the DDS even under fluidic conditions. In the animal experiment, the UUS-MBs in the acoustic lens treatment group had a higher concentration of DOX in the tumor than the control group. Our system suggests uses an acoustic lens to increase DDS effectiveness by providing sufficient ultrasound irradiation to the MBs.