4.7 Article

Small flexible automated system for monitoring Caenorhabditis elegans lifespan based on active vision and image processing techniques

期刊

SCIENTIFIC REPORTS
卷 11, 期 1, 页码 -

出版社

NATURE RESEARCH
DOI: 10.1038/s41598-021-91898-6

关键词

-

资金

  1. CDTI agency of the Spanish Ministry of Economy and Competitiveness under the CIEN project SMARTFOODS
  2. Universitat Politecnica de Valencia [20170020-UPV]
  3. Plan Nacional de I+D [RTI2018-094312-B-I00]
  4. European FEDER funds

向作者/读者索取更多资源

A new monitoring machine, SiViS, was developed for analyzing C. elegans cultures seeded with E. coli using standard Petri plates. The system utilizes active vision illumination and image-processing pipelines for motion detection, demonstrating consistent replicates in lifespan experiments and no significant differences compared to manual assays. The flexibility of SiViS allows adaptation to other C. elegans studies beyond longevity assays.
Traditionally Caenorhabditis elegans lifespan assays are performed by manually inspecting nematodes with a dissection microscope, which involves daily counting of live/dead worms cultured in Petri plates for 21-25 days. This manual inspection requires the screening of hundreds of worms to ensure statistical robustness, and is therefore a time-consuming approach. In recent years, various automated artificial vision systems have been reported to increase the throughput, however they usually provide less accurate results than manual assays. The main problems identified when using these vision systems are the false positives and false negatives, which occur due to culture media changes, occluded zones, dirtiness or condensation of the Petri plates. In this work, we developed and described a new C. elegans monitoring machine, SiViS, which consists of a flexible and compact platform design to analyse C. elegans cultures using the standard Petri plates seeded with E. coli. Our system uses an active vision illumination technique and different image-processing pipelines for motion detection, both previously reported, providing a fully automated image processing pipeline. In addition, this study validated both these methods and the feasibility of the SiViS machine for lifespan experiments by comparing them with manual lifespan assays. Results demonstrated that the automated system yields consistent replicates (p-value log rank test 0.699), and there are no significant differences between automated system assays and traditionally manual assays (p-value 0.637). Finally, although we have focused on the use of SiViS in longevity assays, the system configuration is flexible and can, thus, be adapted to other C. elegans studies such as toxicity, mobility and behaviour.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据