4.6 Article

Serum Occludin Level Combined With NIHSS Score Predicts Hemorrhage Transformation in Ischemic Stroke Patients With Reperfusion

期刊

FRONTIERS IN CELLULAR NEUROSCIENCE
卷 15, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fncel.2021.714171

关键词

occludin; hemorrhagic transformation; acute ischemic stroke; blood-brain barrier; NIHSS score

资金

  1. National Natural Science Foundation of China [81620108011]
  2. Beijing Nova Programme Interdisciplinary Cooperation Project [Z191100001119002]

向作者/读者索取更多资源

Serum occludin level and baseline NIHSS score are independently associated with hemorrhagic transformation (HT) in acute ischemic stroke patients with reperfusion therapy. The combination of these two variables significantly improves the accuracy of HT prediction.
Hemorrhagic transformation (HT) is a severe complication following acute ischemic stroke, particularly with reperfusion interventions, leading to poor prognosis. Serum occludin level is related with blood brain barrier disruption, and the National Institute of Health stroke scale (NIHSS) score reflects stroke severity. We investigated whether the two covariates are independently associated with HT and their combination can improve the accuracy of HT prediction in ischemic stroke patients with reperfusion therapy. Seventy-six patients were screened from the established database of acute ischemic stroke in our previous study, which contains all clinical information, including serum occludin levels, baseline NIHSS score, and hemorrhagic events. Multivariate logistic regression analysis showed that serum occludin level (OR = 4.969, 95% CI: 2.069-11.935, p < 0.001) and baseline NIHSS score (OR = 1.293, 95% CI 1.079-1.550, p = 0.005) were independent risk factors of HT after adjusting for potential confounders. Compared with non-HT patients, HT patients had higher baseline NIHSS score [12 (10.5-18.0) versus 6 (4-12), p = 0.003] and serum occludin level (5.47 +/- 1.25 versus 3.81 +/- 1.19, p < 0.001). Moreover, receiver operating characteristic curve based on leave-one-out cross-validation showed that the combination of serum occludin level and NIHSS score significantly improved the accuracy of predicting HT (0.919, 95% CI 0.857-0.982, p < 0.001). These findings suggest that the combination of two methods may provide a better tool for HT prediction in acute ischemic stroke patients with reperfusion therapy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据