4.8 Article

In-situ 3D fouling visualization of membrane distillation treating industrial textile wastewater by optical coherence tomography imaging

期刊

WATER RESEARCH
卷 205, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2021.117668

关键词

Optical coherence tomography (OCT); Membrane distillation; Membrane fouling; In situ and non-invasive visualization

资金

  1. Research Grant Council of Hong Kong through General Research Fund [11213819]
  2. Theme-based Research Scheme [T21-604/19-R]

向作者/读者索取更多资源

Membrane fouling in membrane distillation (MD) applications can reduce system performance and increase operational costs. A new advanced 3D imaging analysis technique using Optical Coherence Tomography was proposed, allowing real-time evaluation of fouling layer formation and characteristics. The C-PTFE membrane demonstrated superior antifouling ability compared to C-PVDF, showing a potential for lowering operational costs and improving system stability.
Membrane fouling, which is caused by the deposition of particles on the membrane surface or pores, reduces system performance in membrane distillation (MD) applications, resulting in increased operational costs, poor recovery, and system failure. Optical Coherence Tomography enables in-situ foulant monitoring in both 2D and 3D, however, the 2D images can only determine fouling layer thickness in severe fouling. Therefore, in this study, an advanced 3D imaging analysis technique using intensity range filters was proposed to quantify fouling layer formation during MD through the use of a single 3D image. This approach not only reduces computational power requirements, but also successfully separated the fouling layer from the membrane at the microscale. Thus, the thickness, fouling index, and fouling layer coverage can be evaluated in real time. To test this approach, Polyvinylidene fluoride (C-PVDF) and polytetrafluoroethylene (C-PTFE) membranes were used to treat a feed consisting of industrial textile wastewater. Thin and disperse foulants was observed on the C-PTFE, with a 22 mu m thick fouling layer which could not be observed using 2D images after 24 h. Moreover, the C-PTFE demonstrated better antifouling ability than the C-PVDF as demonstrated by its lower fouling index, which was also supported by surface energy characterization. This work demonstrates the significant potential of 3D imagery in the longterm monitoring of membrane fouling process to improve membrane antifouling performance in MD applications, which can lead to lowered operational costs and improved system stability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。