4.7 Article

Simulation and performance study of circular ultrasonic array for tubes' internal inspection

期刊

ULTRASONICS
卷 116, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ultras.2021.106508

关键词

Phased array ultrasonic testing (PAUT); Circular array transducer; Internal inspection; Tube

资金

  1. Chinese National ST Major Project [ZX069]

向作者/读者索取更多资源

The development and validation of a CA transducer for internal inspection of small diameter tubes demonstrated high detection sensitivity, with experimental results showing at least 0.2 mm circumferential and 0.1 mm radial detection capability.
A circular array (CA) transducer is developed and validated to implement internal inspection of the small diameter tubes, one of whose potential application targets is the heat exchanger tubes in Modular High Temperature Gas-cooled Reactor. A geometric model of the transducer and the delay law are proposed according to the inspection setup. Using k-Wave, an open source acoustic simulation toolbox, the beam profiles of various aperture sizes are analyzed to select a suitable aperture. The beams with different focal depths are compared to verify the delay law and to choose a preferable focus. Reflector responses are simulated to predict the transducer's detection sensitivity. To validate the simulation results, a prototype transducer composed of 64 elements is fabricated. Its electrical and acoustical performances are acquired with a pulser-receiver. A 4-element aperture with the focal depth of 1.0 mm is selected to perform internal inspection experiment according to the simulation results. The eight longitudinal grooves with widths of 0.2, 0.3, 0.4, and 0.5 mm on inner and outer tube walls are applied as typical reflectors to test circumferential detection sensitivity. The other five grooves with depths from 0.1 mm to 0.5 mm are chosen to verify radial detection sensitivity. The experiment results demonstrate the detection sensitivity of the CA transducer reaches at least 0.2 mm in circumferential direction and 0.1 mm in radial direction. The CA is proven capable of inspecting small diameter tubes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据