4.6 Article

Progesterone release profile and follicular development in Holstein cows receiving intravaginal progesterone devices

期刊

THERIOGENOLOGY
卷 172, 期 -, 页码 207-215

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.theriogenology.2021.07.001

关键词

Steroid hormone; Device; Dominant follicle; Dairy cow; Bos taurus

资金

  1. Sa~o Paulo Research Foundation (FAPESP)
  2. National Council for Scientific and Technological Development (CNPq)
  3. Coordination for the Improvement of Higher Education Personnel (CAPES) of Brazil

向作者/读者索取更多资源

This study evaluated the progesterone release profiles of different commercial intravaginal devices and their effects on the development of the dominant follicle in non-lactating Holstein cows. The circulating progesterone concentrations produced by the devices were found to influence the growth rate of the dominant follicle during the treatment period.
The aim of this study was to evaluate the progesterone (P4) release profile provided by eight commercial intravaginal P4 devices, as well as the effect of circulating P4 concentrations produced exclusively by these devices on the development of the dominant follicle (DF) in non-lactating multiparous Holstein cows. All cows were submitted to the same experimental design starting with the insertion of a reused P4 device (2 g -original P4 load) for 7 d, followed by two treatments of cloprostenol sodium (PGF; 0.482 mg), 24 h apart, 6 and 7 d after device insertion. Just before device removal, a Norgestomet ear implant was inserted and, 2 d later (Day 0), simultaneously to Norgestomet withdrawal, cows received one of the tested intravaginal devices and 2 mg of estradiol benzoate (EB) im. In Exp.1 (n = 22; three replicates), cows were randomized to receive: CIDR (1.38 g); PRID-Delta (1.55 g); Prociclar (0.75 g); or Repro sync (2 g). In Exp. 2 (n = 29; four replicates), cows were randomized to receive: Cue-Mate (1.56 g); DIB 0.5 (0.5 g); DIB (1 g); PRID-Delta (1.55 g); or Sincrogest (1 g). Blood samples were collected before P4 device insertion (Day 0), 12 h later and daily over 15 d (1 d after P4 device removal). Ultrasound examinations were performed to evaluate growth of the DF on Days 0, 7, 8, 9, and 10. Results are presented as mean +/- SEM and differences were considered when P < 0.05. Overall, the circulating P4 profile and mean circulating P4 over 10 d differed among treatments. However, no effects were observed on the DF diameter and follicular growth rate from Day 7-10 after P4 device insertion. In Exp. 2, devices that provided higher circulating P4 concentrations were associated to a slower DF growth during the treatment period. Finally, this study provided a better understanding of the P4 release profile produced by intravaginal P4 devices as well as their effect on circulating P4 concentrations and DF development in non-lactating Holstein cows. (c) 2021 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据