4.7 Article

Metal-coded hydrogel magnetic molecularly imprinted polymer for preconcentration and cleanup of sarcosine: Determination in urine; coupled to on-column capillary electrophoresis

期刊

TALANTA
卷 230, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2021.122309

关键词

Hydrogel; Magnetic molecularly imprinted polymers; Amino acids; Prostate cancer; Sarcosine

资金

  1. Ahvaz Jundishapur University of Medical Sciences [N112]
  2. Iran National Science Foundation (INSF) [95849362]

向作者/读者索取更多资源

In this study, a novel sarcosine metal-coded hydrogel magnetic molecularly imprinted polymer was successfully fabricated and applied for the extraction and quantification of sarcosine in urine samples. The method employed on-column derivatization capillary electrophoresis to separate and detect multiple amino acids, achieving satisfactory detection results.
In this study, sarcosine metal-coded hydrogel magnetic molecularly imprinted polymer (Hydro-MeC-MMIP) has been fabricated and coupled to on-column derivatization capillary electrophoresis (CE). As a metal-coding approach, sarcosine-Cu2+-ligand (Sar-Cu2+-L) chelate complex was introduced as a template to overcome the problems associated with the fabrication of MMIP for a small molecule having limited functional groups such as sarcosine. To our best knowledge, it is the first time that methacrylamide (MA) coated Fe3O4 (Fe3O4@MA) with abounded reactive double-bound on the surface has been used as a magnetic core in the one-pot synthesis of MMIPs. As prepared, Hydro-MeC-MMIP was characterized by different microscopic, spectroscopic, and thermal gravimetric methods. Hydro-MeC-MMIP was used to extract and preconcentrate sarcosine in the urine sample with no treatment and dilution. Sarcosine was quantified by on-column derivatization capillary electrophoresis equipped with a photodiode array detector. A mixture of thirteen amino acids was separated with a total run time of 12 min. Three structural analogs, including alanine, sarcosine, and glycine, were significantly resolved. Under optimal experimental conditions, the method's detection and quantification limits were 9.93 and 33.10 ng mL(-1), respectively. The linear range of 50-2000 ng mL(-1) and 96% recovery, along with the relative standard deviation of 6.07% (n = 6) for the target amino acid, were obtained. This method provides a simple, low-cost, fast, and efficient tool for extracting and quantifying sarcosine in the urine. The present method can address inconsistency in evaluating sarcosine as a candidate biomarker for prostate cancer with a simple CE/UV; no need for a sophisticated detection system such as a mass spectrometer.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据