4.1 Article

Effect of Remote Cardiac Monitoring System Design on Response Time to Critical Arrhythmias

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/SIH.0000000000000610

关键词

Arrhythmia simulation; remote telemetry monitoring

资金

  1. Agency for Healthcare Research and Quality [R01HS023387]

向作者/读者索取更多资源

This study investigated the efficiency of different monitoring systems in detecting and responding to critical arrhythmias through simulated experiments. The results showed that systems with an intermediary communicating critical events between monitor watchers and nurses had faster response times to simulated arrhythmias.
Introduction In many hospitals across the country, electrocardiograms of multiple at-risk patients are monitored remotely by telemetry monitor watchers in a central location. However, there is limited evidence regarding best practices for designing these cardiac monitoring systems to ensure prompt detection and response to life-threatening events. To identify factors that may affect monitoring efficiency, we simulated critical arrhythmias in inpatient units with different monitoring systems and compared their efficiency in communicating the arrhythmias to a first responder. Methods This was a multicenter cross-sectional in situ simulation study. Simulation participants were monitor watchers and first responders (usually nurses) in 2 inpatient units in each of 3 hospitals. Manipulated variables included: (1) number of communication nodes between monitor watchers and first responders; (2) central monitoring station location-on or off the patient care unit; (3) monitor watchers' workload; (4) nurses' workload; and (5) participants' experience. Results We performed 62 arrhythmia simulations to measure response times of monitor watchers and 128 arrhythmia simulations to measure response times in patient care units. We found that systems in which an intermediary between monitor watchers and nurses communicated critical events had faster response times to simulated arrhythmias than systems in which monitor watchers communicated directly with nurses. Responses were also faster in units colocated with central monitoring stations than in those located remotely. As the perceived workload of nurses increased, response latency also increased. Experience did not affect response times. Conclusions Although limited in our ability to isolate the effects of these factors from extraneous factors on central monitoring system efficiency, our study provides a roadmap for using in situ arrhythmia simulations to assess and improve monitoring performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据