Intrafraction motion during partial breast irradiation depends on treatment time

期刊

RADIOTHERAPY AND ONCOLOGY
卷 159, 期 -, 页码 176-182

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.radonc.2021.03.029

关键词

Breast cancer; Partial breast irradiation; Intrafraction motion; Geometric accuracy; Breathing motion; Drift

资金

  1. Accuray Inc., Sunnyvale, USA

向作者/读者索取更多资源

In this study, APBI treatment fractions on Cyberknife were assessed to determine that the margin needed to compensate for intrafraction motion increased with longer fraction durations due to drifting of the target. Breathing motion has a limited effect on margin adjustments.
Introduction: As the prognosis of early-stage breast cancer patients is excellent, prevention of radiation induced toxicity has become crucial. Reduction of margins compensating for intrafraction motion reduces non-target dose. We assessed motion of the tumor bed throughout APBI treatment fractions and calculated CTV-PTV margins for breathing and drift. Methods: This prospective clinical trial included patients treated with APBI on a Cyberknife with fiducial tracking. Paired orthogonal kV images made throughout the entire fraction were used to extract the tumor bed position. The images used for breathing modelling were used to calculate breathing amplitudes. The margins needed to compensate for breathing and drift were calculated according to Engelsman and Van Herk respectively. Results: Twenty-two patients, 110 fractions and 5087 image pairs were analyzed. The margins needed for breathing were 0.3-0.6 mm. The margin for drift increased with time after the first imaging for positioning. For a total fraction duration up to 8 min, a margin of 1.0 mm is sufficient. For a fraction of 32 min, 2.5 mm is needed. Techniques that account for breathing motion can reduce the margin by 0.1 mm. There was a systematic trend in the drift in the caudal, medial and posterior direction. To compensate for this, 0.7 mm could be added to the margins. Conclusions: The margin needed to compensate for intrafraction motion increased with longer fraction duration due to drifting of the target. It doubled for a fraction of 24 min compared to 8 min. Breathing motion has a limited effect. (c) 2021 The Authors. Published by Elsevier B.V. Radiotherapy and Oncology 159 (2021) 176-182 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据