4.6 Article

Characterization of gamma-ray and neutron radiation absorption properties of synthesized quinoline derivatives and their genotoxic potential

期刊

RADIATION PHYSICS AND CHEMISTRY
卷 184, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.radphyschem.2021.109471

关键词

Monte Carlo simulation; Quinoline derivatives; Gamma; Neutron; Drug

向作者/读者索取更多资源

This study synthesized six different types of quinoline derivatives for potential use as an anti-radiation drug, and assessed their effectiveness against radiation through Monte Carlo simulation and experimental measurements. Results showed that the quinoline derivative shielding material performed better than traditional materials in absorbing radiation, and the derivatives were found to be genotoxically safe at tested concentrations. It is suggested that these new radiation shielding derivatives could be used as active ingredients in drugs developed to combat both neutron and gamma radiation.
In this study, six different types of quinoline derivatives were synthesized, which can be used as an anti-radiation drug for active matter and its effects against radiation was determined. The effective removal cross-sections, mean free path, halfvalue layer and neutron transmission number were calculated for fast neutron radiation using the Monte Carlo simulation GEANT4 and FLUKA codes. Gamma radiation shielding parameters such as mass attenuation coefficient (MAC), effective atom number (Zeff), mean free path (MFP), exposure buildup factor (EBF) and halfvalue layer (HVL) were theoretically calculated using WinXCom and Phy-X/PSD software. Neutron equivalent dose measurements were performed using a 241Am-Be fast neutron source and a BF3 gas detector with 4.5 MeV of energy and 74 GBq activity. Both simulation and experimental measurements were compared with paraffin and conventional concrete. It was found that the quinoline derivative shielding material absorbed radiation much better than these reference materials. Additionally, the genotoxic potentials of the derivatives were assessed by using the yeast DEL assay and the results revealed that the derivatives can be considered genotoxically safe at the tested concentrations (up to 5 mM). It has been suggested that this new radiation shielding derivatives material can be used as active ingredients for a drug to be developed against both neutron and gamma radiation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据