4.6 Article

miR-361-5p as a promising qRT-PCR internal control for tumor and normal breast tissues

期刊

PLOS ONE
卷 16, 期 6, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0253009

关键词

-

向作者/读者索取更多资源

In this study, a multi-component scoring system was used to identify the most stable miRNA, hsa-miR-361-5p, in breast tissues using TCGA miRNA-Seq data. This miRNA was recommended as a suitable reference gene for miRNA expression studies in breast cancer. Furthermore, the commonly used IC hsa-miR-16-5p was shown to be unsuitable for breast cancer studies.
Background One of the most widely used evaluation methods in miRNA experiments is qRT-PCR. However, selecting suitable internal controls (IC) is crucial for qRT-PCR experiments. Currently, there is no consensus on the ICs for miRNA qRT-PCR experiments in breast cancer. To this end, we tried to identify the most stable (the least expression alteration) and promising miRNAs in normal and tumor breast tissues by employing TCGA miRNA-Seq data and then experimentally validated them on fresh clinical samples. Methods A multi-component scoring system was used which takes into account multiple expression stability criteria as well as correlation with clinical characteristics. Furthermore, we extended the scoring system for more than two biological sub-groups. TCGA BRCA samples were analyzed based on two grouping criteria: Tumor & Normal samples and Tumor subtypes. The top 10 most stable miRNAs were further investigated by differential expression and survival analysis. Then, we examined the expression level of the top scored miRNA (hsa-miR-361-5p) along with two commonly used ICs hsa-miR-16-5p and U48 on 34 pairs of Primary breast tumor and their adjacent normal tissues using qRT-PCR. Results According to our multi-component scoring system, hsa-miR-361-5p had the highest stability score in both grouping criteria and hsa-miR-16-5p showed significantly lower scores. Based on our qRT-PCR assay, while U48 was the most abundant IC, hsa-miR-361-5p had lower standard deviation and also was the only IC capable of detecting a significant up-regulation of hsa-miR-21-5p in breast tumor tissue. Conclusions miRNA-Seq data is a great source to discover stable ICs. Our results demonstrated that hsa-miR-361-5p is a highly stable miRNA in tumor and non-tumor breast tissue and we recommend it as a suitable reference gene for miRNA expression studies in breast cancer. Additionally, although hsa-miR-16-5p is a commonly used IC, it's not a suitable one for breast cancer studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据