Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia

期刊

PLOS ONE
卷 16, 期 5, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0252091

关键词

-

资金

  1. Hungarian-Romanian Cross-Border Cooperation Project (HU-RO) [0802/008 SCREENGEN]
  2. Institutional Account Program of the University of Szeged, Szeged, Hungary [5121]

向作者/读者索取更多资源

This study compared five different QC preparation approaches for CAH diagnostics in dried blood spots, finding that four techniques produced similar results in terms of reproducibility and concentration ranges, while the third technique showed significantly lower concentrations in some cases. These findings have implications for the in-house preparation of QC samples in laboratory developed tests for CAH.
In newborn screening, samples suspected for congenital adrenal hyperplasia (CAH), a potentially lethal inborn error of steroid biosynthesis, need to be confirmed using liquid chromatography-tandem mass spectrometry. Daily quality controls (QCs) for the 2(nd)-tier CAH assay are not commercially available and are therefore generally prepared within the laboratory. For the first time, we aimed to compare five different QC preparation approaches used in routine diagnostics for CAH on the concentrations of cortisol, 21-deoxycortisol, 11-deoxycortisol, 4-androstenedione and 17-hydroxyprogesterone in dried blood spots. The techniques from Prep1 to Prep5 were tested at two analyte concentrations by spiking aliquots of a steroid-depleted blood, derived from washed erythrocyte suspension and steroid-depleted serum. The preparation processes differed in the sequence of the preparation steps and whether freeze-thaw cycles were used to facilitate blood homogeneity. The five types of dried blood spot QCs were assayed and quantitated in duplicate on five different days using a single calibration row per day. Inter-assay variations less than 15% and concentrations within +/- 15% of the nominal values were considered acceptable. Results obtained by means of the four dried blood spot QC preparation techniques (Prep1, Prep2, Prep4 and Prep5) were statistically similar and remained within the +/- 15% ranges in terms of both reproducibility and nominal values. However, concentration results for Prep3 (spiking prior to three freeze-thaw cycles) were significantly lower than the nominal values in this setting, with differences exceeding the +/- 15% range in many cases despite acceptable inter-assay variations. These findings have implications for the in-house preparation of QC samples in laboratory developed tests for CAH, including 2(nd)-tier assays in newborn screening.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据