4.6 Article

Development and ex-vivo assessment of a novel patient specific guide and instrumentation system for minimally invasive total shoulder arthroplasty

期刊

PLOS ONE
卷 16, 期 5, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0251880

关键词

-

资金

  1. Leverhulme Trust
  2. Wellcome Trust Translation Fund award [098269/Z/12/Z]
  3. Wellcome Trust [098269/Z/12/Z] Funding Source: Wellcome Trust

向作者/读者索取更多资源

The novel guidance technique and instrumentation system for minimally invasive short-stemmed total shoulder arthroplasty achieves similar accuracy to traditional open techniques while reducing complications, potentially leading to improved rehabilitation and functional outcomes for patients with moderate arthritis.
Objective To develop and assess a novel guidance technique and instrumentation system for minimally invasive short-stemmed total shoulder arthroplasty that will help to reduce the complications associated with traditional open replacement such as poor muscle healing and neurovascular injury. We have answered key questions about the developed system including (1) can novel patient-specific guides be accurately registered and used within a minimally invasive environment?; (2) can accuracy similar to traditional techniques be achieved? Methods A novel intra-articular patient-specific guide was developed for use with a new minimally invasive posterior surgical approach that guides bone preparation without requiring muscle resection or joint dislocation. Additionally, a novel set of instruments were developed to enable bone preparation within the minimally invasive environment. The full procedure was evaluated in six cadaveric shoulders, using digitizations to assess accuracy of each step. Results Patient-specific guide registration accuracy in 3D translation was 2.21.2mm (RMSE1 SD; p = 0.007) for the humeral component and 2.7 +/- 0.7mm (p<0.001) for the scapula component. Final implantation accuracy was 2.9 +/- 3.0mm (p = 0.066) in translation and 5.7-6.8 +/- 2.2-4.0 degrees (0.001 <0.009) across the humerus implants' three rotations. Similarly, the glenoid component's implantation accuracy was 3.0 +/- 1.7mm (p = 0.008) in translation and 2.3-4.3 +/- 2.2-4.4 degrees (0.008 <0.09) in rotation. Conclusion This system achieves minimally invasive shoulder replacement with accuracy similar to traditional open techniques while avoiding common causes of complications. Significance This novel technique could lead to a paradigm shift in shoulder arthroplasty for patients with moderate arthritis, which could significantly improve rehabilitation and functional outcomes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据