The study utilized smartphones to predict anemia and screen for hemoglobin concentration in patients. Results showed varying accuracy and specificity at different transfusion thresholds, influenced by factors such as image quality and HBl values. Further improvements in image quality and computational corrections can enhance hemoglobin estimates.
Anemia, defined as a low hemoglobin concentration, has a large impact on the health of the world's population. We describe the use of a ubiquitous device, the smartphone, to predict hemoglobin concentration and screen for anemia. This was a prospective convenience sample study conducted in Emergency Department (ED) patients of an academic teaching hospital. In an algorithm derivation phase, images of both conjunctiva were obtained from 142 patients in Phase 1 using a smartphone. A region of interest targeting the palpebral conjunctiva was selected from each image. Image-based parameters were extracted and used in stepwise regression analyses to develop a prediction model of estimated hemoglobin (HBc). In Phase 2, a validation model was constructed using data from 202 new ED patients. The final model based on all 344 patients was tested for accuracy in anemia and transfusion thresholds. Hemoglobin concentration ranged from 4.7 to 19.6 g/dL (mean 12.5). In Phase 1, there was a significant association between HBc and laboratory-predicted hemoglobin (HBl) slope = 1.07 (CI = 0.98-1.15), p<0.001. Accuracy, sensitivity, and specificity of HBc for predicting anemia was 82.9 [79.3, 86.4], 90.7 [87.0, 94.4], and 73.3 [67.1, 79.5], respectively. In Phase 2, accuracy, sensitivity and specificity decreased to 72.6 [71.4, 73.8], 72.8 [71, 74.6], and 72.5 [70.8, 74.1]. Accuracy for low (<7 g/dL) and high (<9 g/dL) transfusion thresholds was 94.4 [93.7, 95] and 86 [85, 86.9] respectively. Error trended with increasing HBl values (slope 0.27 [0.19, 0.36] and intercept -3.14 [-4.21, -2.07] (p<0.001) such that HBc tended to underestimate hemoglobin in higher ranges and overestimate in lower ranges. Higher quality images had a smaller bias trend than lower quality images. When separated by skin tone results were unaffected. A smartphone can be used in screening for anemia and transfusion thresholds. Improvements in image quality and computational corrections can further enhance estimates of hemoglobin.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据